OSDN Git Service

PR target/50678
[pf3gnuchains/gcc-fork.git] / gcc / ada / lib.ads
1 ------------------------------------------------------------------------------
2 --                                                                          --
3 --                         GNAT COMPILER COMPONENTS                         --
4 --                                                                          --
5 --                                  L I B                                   --
6 --                                                                          --
7 --                                 S p e c                                  --
8 --                                                                          --
9 --          Copyright (C) 1992-2010, Free Software Foundation, Inc.         --
10 --                                                                          --
11 -- GNAT is free software;  you can  redistribute it  and/or modify it under --
12 -- terms of the  GNU General Public License as published  by the Free Soft- --
13 -- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14 -- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE.                                     --
17 --                                                                          --
18 -- As a special exception under Section 7 of GPL version 3, you are granted --
19 -- additional permissions described in the GCC Runtime Library Exception,   --
20 -- version 3.1, as published by the Free Software Foundation.               --
21 --                                                                          --
22 -- You should have received a copy of the GNU General Public License and    --
23 -- a copy of the GCC Runtime Library Exception along with this program;     --
24 -- see the files COPYING3 and COPYING.RUNTIME respectively.  If not, see    --
25 -- <http://www.gnu.org/licenses/>.                                          --
26 --                                                                          --
27 -- GNAT was originally developed  by the GNAT team at  New York University. --
28 -- Extensive contributions were provided by Ada Core Technologies Inc.      --
29 --                                                                          --
30 ------------------------------------------------------------------------------
31
32 --  This package contains routines for accessing and outputting the library
33 --  information. It contains the routine to load subsidiary units.
34
35 with Alloc;
36 with Namet; use Namet;
37 with Table;
38 with Types; use Types;
39
40 package Lib is
41
42    type Compiler_State_Type is (Parsing, Analyzing);
43    Compiler_State : Compiler_State_Type;
44    --  Indicates current state of compilation. This is used to implement the
45    --  function In_Extended_Main_Source_Unit.
46
47    Parsing_Main_Extended_Source : Boolean := False;
48    --  Set True if we are currently parsing a file that is part of the main
49    --  extended source (the main unit, its spec, or one of its subunits). This
50    --  flag to implement In_Extended_Main_Source_Unit.
51
52    Analysing_Subunit_Of_Main : Boolean := False;
53    --  Set to True when analyzing a subunit of the main source. When True, if
54    --  the subunit is preprocessed and -gnateG is specified, then the
55    --  preprocessed file (.prep) is written.
56
57    --------------------------------------------
58    -- General Approach to Library Management --
59    --------------------------------------------
60
61    --  As described in GNote #1, when a unit is compiled, all its subsidiary
62    --  units are recompiled, including the following:
63
64    --    (a) Corresponding spec for a body
65    --    (b) Parent spec of a child library spec
66    --    (d) With'ed specs
67    --    (d) Parent body of a subunit
68    --    (e) Subunits corresponding to any specified stubs
69    --    (f) Bodies of inlined subprograms that are called
70    --    (g) Bodies of generic subprograms or packages that are instantiated
71    --    (h) Bodies of packages containing either of the above two items
72    --    (i) Specs and bodies of runtime units
73    --    (j) Parent specs for with'ed child library units
74
75    --  If a unit is being compiled only for syntax checking, then no subsidiary
76    --  units are loaded, the syntax check applies only to the main unit,
77    --  i.e. the one contained in the source submitted to the library.
78
79    --  If a unit is being compiled for syntax and semantic checking, then only
80    --  cases (a)-(d) loads are performed, since the full semantic checking can
81    --  be carried out without needing (e)-(i) loads. In this case no object
82    --  file, or library information file, is generated, so the missing units
83    --  do not affect the results.
84
85    --  Specifications of library subprograms, subunits, and generic specs
86    --  and bodies, can only be compiled in syntax/semantic checking mode,
87    --  since no code is ever generated directly for these units. In the case
88    --  of subunits, only the compilation of the ultimate parent unit generates
89    --  actual code. If a subunit is submitted to the compiler in syntax/
90    --  semantic checking mode, the parent (or parents in the nested case) are
91    --  semantically checked only up to the point of the corresponding stub.
92
93    --  If code is being generated, then all the above units are required,
94    --  although the need for bodies of inlined procedures can be suppressed
95    --  by the use of a switch that sets the mode to ignore pragma Inline
96    --  statements.
97
98    --  The two main sections of the front end, Par and Sem, are recursive.
99    --  Compilation proceeds unit by unit making recursive calls as necessary.
100    --  The process is controlled from the GNAT main program, which makes calls
101    --  to Par and Sem sequence for the main unit.
102
103    --  Par parses the given unit, and then, after the parse is complete, uses
104    --  the Par.Load subprogram to load all its subsidiary units in categories
105    --  (a)-(d) above, installing pointers to the loaded units in the parse
106    --  tree, as described in a later section of this spec. If any of these
107    --  required units is missing, a fatal error is signalled, so that no
108    --  attempt is made to run Sem in such cases, since it is assumed that
109    --  too many cascaded errors would result, and the confusion would not
110    --  be helpful.
111
112    --  Following the call to Par on the main unit, the entire tree of required
113    --  units is thus loaded, and Sem is called on the main unit. The parameter
114    --  passed to Sem is the unit to be analyzed. The visibility table, which
115    --  is a single global structure, starts out containing only the entries
116    --  for the visible entities in Standard. Every call to Sem establishes a
117    --  new scope stack table, pushing an entry for Standard on entry to provide
118    --  the proper initial scope environment.
119
120    --  Sem first proceeds to perform semantic analysis on the currently loaded
121    --  units as follows:
122
123    --    In the case of a body (case (a) above), Sem analyzes the corresponding
124    --    spec, using a recursive call to Sem. As is always expected to be the
125    --    case with calls to Sem, any entities installed in the visibility table
126    --    are removed on exit from Sem, so that these entities have to be
127    --    reinstalled on return to continue the analysis of the body which of
128    --    course needs visibility of these entities.
129    --
130    --    In the case of the parent of a child spec (case (b) above), a similar
131    --    call is made to Sem to analyze the parent. Again, on return, the
132    --    entities from the analyzed parent spec have to be installed in the
133    --    visibility table of the caller (the child unit), which must have
134    --    visibility to the entities in its parent spec.
135
136    --    For with'ed specs (case (c) above), a recursive call to Sem is made
137    --    to analyze each spec in turn. After all the spec's have been analyzed,
138    --    but not till that point, the entities from all the with'ed units are
139    --    reinstalled in the visibility table so that the caller can proceed
140    --    with the analysis of the unit doing the with's with the necessary
141    --    entities made either potentially use visible or visible by selection
142    --    as needed.
143
144    --    Case (d) arises when Sem is passed a subunit to analyze. This means
145    --    that the main unit is a subunit, and the unit passed to Sem is either
146    --    the main unit, or one of its ancestors that is still a subunit. Since
147    --    analysis must start at the top of the tree, Sem essentially cancels
148    --    the current call by immediately making a call to analyze the parent
149    --    (when this call is finished it immediately returns, so logically this
150    --    call is like a goto). The subunit will then be analyzed at the proper
151    --    time as described for the stub case. Note that we also turn off the
152    --    indication that code should be generated in this case, since the only
153    --    time we generate code for subunits is when compiling the main parent.
154
155    --    Case (e), subunits corresponding to stubs, are handled as the stubs
156    --    are encountered. There are three sub-cases:
157
158    --      If the subunit has already been loaded, then this means that the
159    --      main unit was a subunit, and we are back on our way down to it
160    --      after following the initial processing described for case (d).
161    --      In this case we analyze this particular subunit, as described
162    --      for the case where we are generating code, but when we get back
163    --      we are all done, since the rest of the parent is irrelevant. To
164    --      get out of the parent, we raise the exception Subunit_Found, which
165    --      is handled at the outer level of Sem.
166
167    --      The cases where the subunit has not already been loaded correspond
168    --      to cases where the main unit was a parent. In this case the action
169    --      depends on whether or not we are generating code. If we are not
170    --      generating code, then this is the case where we can simply ignore
171    --      the subunit, since in checking mode we don't even want to insist
172    --      that the subunit exist, much less waste time checking it.
173
174    --      If we are generating code, then we need to load and analyze
175    --      all subunits. This is achieved with a call to Lib.Load to load
176    --      and parse the unit, followed by processing that installs the
177    --      context clause of the subunit, analyzes the subunit, and then
178    --      removes the context clause (from the visibility chains of the
179    --      parent). Note that we do *not* do a recursive call to Sem in
180    --      this case, precisely because we need to do the analysis of the
181    --      subunit with the current visibility table and scope stack.
182
183    --    Case (f) applies only to subprograms for which a pragma Inline is
184    --    given, providing that the compiler is operating in the mode where
185    --    pragma Inline's are activated. When the expander encounters a call
186    --    to such a subprogram, it loads the body of the subprogram if it has
187    --    not already been loaded, and calls Sem to process it.
188
189    --    Case (g) is similar to case (f), except that the body of a generic
190    --    is unconditionally required, regardless of compiler mode settings.
191    --    As in the subprogram case, when the expander encounters a generic
192    --    instantiation, it loads the generic body of the subprogram if it
193    --    has not already been loaded, and calls Sem to process it.
194
195    --    Case (h) arises when a package contains either an inlined subprogram
196    --    which is called, or a generic which is instantiated. In this case the
197    --    body of the package must be loaded and analyzed with a call to Sem.
198
199    --    Case (i) is handled by adding implicit with clauses to the context
200    --    clauses of all units that potentially reference the relevant runtime
201    --    entities. Note that since we have the full set of units available,
202    --    the parser can always determine the set of runtime units that is
203    --    needed. These with clauses do not have associated use clauses, so
204    --    all references to the entities must be by selection. Once the with
205    --    clauses have been added, subsequent processing is as for normal
206    --    with clauses.
207
208    --    Case (j) is also handled by adding appropriate implicit with clauses
209    --    to any unit that withs a child unit. Again there is no use clause,
210    --    and subsequent processing proceeds as for an explicit with clause.
211
212    --  Sem thus completes the loading of all required units, except those
213    --  required for inline subprogram bodies or inlined generics. If any
214    --  of these load attempts fails, then the expander will not be called,
215    --  even if code was to be generated. If the load attempts all succeed
216    --  then the expander is called, though the attempt to generate code may
217    --  still fail if an error occurs during a load attempt for an inlined
218    --  body or a generic body.
219
220    -------------------------------------------
221    -- Special Handling of Subprogram Bodies --
222    -------------------------------------------
223
224    --  A subprogram body (in an adb file) may stand for both a spec and a body.
225    --  A simple model (and one that was adopted through version 2.07) is simply
226    --  to assume that such an adb file acts as its own spec if no ads file is
227    --  is present.
228
229    --  However, this is not correct. RM 10.1.4(4) requires that such a body
230    --  act as a spec unless a subprogram declaration of the same name is
231    --  already present. The correct interpretation of this in GNAT library
232    --  terms is to ignore an existing ads file of the same name unless this
233    --  ads file contains a subprogram declaration with the same name.
234
235    --  If there is an ads file with a unit other than a subprogram declaration
236    --  with the same name, then a fatal message is output, noting that this
237    --  irrelevant file must be deleted before the body can be compiled. See
238    --  ACVC test CA1020D to see how this processing is required.
239
240    -----------------
241    -- Global Data --
242    -----------------
243
244    Current_Sem_Unit : Unit_Number_Type := Main_Unit;
245    --  Unit number of unit currently being analyzed/expanded. This is set when
246    --  ever a new unit is entered, saving and restoring the old value, so that
247    --  it always reflects the unit currently being analyzed. The initial value
248    --  of Main_Unit ensures that a proper value is set initially, and in
249    --  particular for analysis of configuration pragmas in gnat.adc.
250
251    Main_Unit_Entity : Entity_Id;
252    --  Entity of main unit, same as Cunit_Entity (Main_Unit) except where
253    --  Main_Unit is a body with a separate spec, in which case it is the
254    --  entity for the spec.
255
256    -----------------
257    -- Units Table --
258    -----------------
259
260    --  The units table has an entry for each unit (source file) read in by the
261    --  current compilation. The table is indexed by the unit number value,
262    --  The first entry in the table, subscript Main_Unit, is for the main file.
263    --  Each entry in this units table contains the following data.
264
265    --    Unit_File_Name
266    --      The name of the source file containing the unit. Set when the entry
267    --      is created by a call to Lib.Load, and then cannot be changed.
268
269    --    Source_Index
270    --      The index in the source file table of the corresponding source file.
271    --      Set when the entry is created by a call to Lib.Load and then cannot
272    --      be changed.
273
274    --    Munit_Index
275    --      The index of the unit within the file for multiple unit per file
276    --      mode. Set to zero in normal single unit per file mode.
277
278    --    Error_Location
279    --      This is copied from the Sloc field of the Enode argument passed
280    --      to Load_Unit. It refers to the enclosing construct which caused
281    --      this unit to be loaded, e.g. most typically the with clause that
282    --      referenced the unit, and is used for error handling in Par.Load.
283
284    --    Expected_Unit
285    --      This is the expected unit name for a file other than the main unit,
286    --      since these are cases where we load the unit using Lib.Load and we
287    --      know the unit that is expected. It must be the same as Unit_Name
288    --      if it is set (see test in Par.Load). Expected_Unit is set to
289    --      No_Name for the main unit.
290
291    --    Unit_Name
292    --      The name of the unit. Initialized to No_Name by Lib.Load, and then
293    --      set by the parser when the unit is parsed to the unit name actually
294    --      found in the file (which should, in the absence of errors) be the
295    --      same name as Expected_Unit.
296
297    --    Cunit
298    --      Pointer to the N_Compilation_Unit node. Initially set to Empty by
299    --      Lib.Load, and then reset to the required node by the parser when
300    --      the unit is parsed.
301
302    --    Cunit_Entity
303    --      Pointer to the entity node for the compilation unit. Initially set
304    --      to Empty by Lib.Load, and then reset to the required entity by the
305    --      parser when the unit is parsed.
306
307    --    Dependency_Num
308    --      This is the number of the unit within the generated dependency
309    --      lines (D lines in the ALI file) which are sorted into alphabetical
310    --      order. The number is ones origin, so a value of 2 refers to the
311    --      second generated D line. The Dependency_Number values are set
312    --      as the D lines are generated, and are used to generate proper
313    --      unit references in the generated xref information and SCO output.
314
315    --    Dynamic_Elab
316    --      A flag indicating if this unit was compiled with dynamic elaboration
317    --      checks specified (as the result of using the -gnatE compilation
318    --      option or a pragma Elaboration_Checks (Dynamic).
319
320    --    Fatal_Error
321    --      A flag that is initialized to False, and gets set to True if a fatal
322    --      error occurs during the processing of a unit. A fatal error is one
323    --      defined as serious enough to stop the next phase of the compiler
324    --      from running (i.e. fatal error during parsing stops semantics,
325    --      fatal error during semantics stops code generation). Note that
326    --      currently, errors of any kind cause Fatal_Error to be set, but
327    --      eventually perhaps only errors labeled as Fatal_Errors should be
328    --      this severe if we decide to try Sem on sources with minor errors.
329
330    --    Generate_Code
331    --      This flag is set True for all units in the current file for which
332    --      code is to be generated. This includes the unit explicitly compiled,
333    --      together with its specification, and any subunits.
334
335    --    Has_RACW
336    --      A Boolean flag, initially set to False when a unit entry is created,
337    --      and set to True if the unit defines a remote access to class wide
338    --      (RACW) object. This is used for controlling generation of the RA
339    --      attribute in the ali file.
340
341    --    Is_Compiler_Unit
342    --      A Boolean flag, initially set False by default, set to True if a
343    --      pragma Compiler_Unit appears in the unit.
344
345    --    Ident_String
346    --      N_String_Literal node from a valid pragma Ident that applies to
347    --      this unit. If no Ident pragma applies to the unit, then Empty.
348
349    --    Loading
350    --      A flag that is used to catch circular WITH dependencies. It is set
351    --      True when an entry is initially created in the file table, and set
352    --      False when the load is completed, or ends with an error.
353
354    --    Main_Priority
355    --      This field is used to indicate the priority of a possible main
356    --      program, as set by a pragma Priority. A value of -1 indicates
357    --      that the default priority is to be used (and is also used for
358    --      entries that do not correspond to possible main programs).
359
360    --    Main_CPU
361    --      This field is used to indicate the affinity of a possible main
362    --      program, as set by a pragma CPU. A value of -1 indicates
363    --      that the default affinity is to be used (and is also used for
364    --      entries that do not correspond to possible main programs).
365
366    --    Has_Allocator
367    --      This flag is set if a subprogram unit has an allocator after the
368    --      BEGIN (it is used to set the AB flag in the M ALI line).
369
370    --    OA_Setting
371    --      This is a character field containing L if Optimize_Alignment mode
372    --      was set locally, and O/T/S for Off/Time/Space default if not.
373
374    --    Serial_Number
375    --      This field holds a serial number used by New_Internal_Name to
376    --      generate unique temporary numbers on a unit by unit basis. The
377    --      only access to this field is via the Increment_Serial_Number
378    --      routine which increments the current value and returns it. This
379    --      serial number is separate for each unit.
380
381    --    Version
382    --      This field holds the version of the unit, which is computed as
383    --      the exclusive or of the checksums of this unit, and all its
384    --      semantically dependent units. Access to the version number field
385    --      is not direct, but is done through the routines described below.
386    --      When a unit table entry is created, this field is initialized to
387    --      the checksum of the corresponding source file. Version_Update is
388    --      then called to reflect the contributions of any unit on which this
389    --      unit is semantically dependent.
390
391    --  The units table is reset to empty at the start of the compilation of
392    --  each main unit by Lib.Initialize. Entries are then added by calls to
393    --  the Lib.Load procedure. The following subprograms are used to access
394    --  and modify entries in the Units table. Individual entries are accessed
395    --  using a unit number value which ranges from Main_Unit (the first entry,
396    --  which is always for the current main unit) to Last_Unit.
397
398    Default_Main_Priority : constant Int := -1;
399    --  Value used in Main_Priority field to indicate default main priority
400
401    Default_Main_CPU : constant Int := -1;
402    --  Value used in Main_CPU field to indicate default main affinity
403
404    function Cunit            (U : Unit_Number_Type) return Node_Id;
405    function Cunit_Entity     (U : Unit_Number_Type) return Entity_Id;
406    function Dependency_Num   (U : Unit_Number_Type) return Nat;
407    function Dynamic_Elab     (U : Unit_Number_Type) return Boolean;
408    function Error_Location   (U : Unit_Number_Type) return Source_Ptr;
409    function Expected_Unit    (U : Unit_Number_Type) return Unit_Name_Type;
410    function Fatal_Error      (U : Unit_Number_Type) return Boolean;
411    function Generate_Code    (U : Unit_Number_Type) return Boolean;
412    function Ident_String     (U : Unit_Number_Type) return Node_Id;
413    function Has_Allocator    (U : Unit_Number_Type) return Boolean;
414    function Has_RACW         (U : Unit_Number_Type) return Boolean;
415    function Is_Compiler_Unit (U : Unit_Number_Type) return Boolean;
416    function Loading          (U : Unit_Number_Type) return Boolean;
417    function Main_CPU         (U : Unit_Number_Type) return Int;
418    function Main_Priority    (U : Unit_Number_Type) return Int;
419    function Munit_Index      (U : Unit_Number_Type) return Nat;
420    function OA_Setting       (U : Unit_Number_Type) return Character;
421    function Source_Index     (U : Unit_Number_Type) return Source_File_Index;
422    function Unit_File_Name   (U : Unit_Number_Type) return File_Name_Type;
423    function Unit_Name        (U : Unit_Number_Type) return Unit_Name_Type;
424    --  Get value of named field from given units table entry
425
426    procedure Set_Cunit            (U : Unit_Number_Type; N : Node_Id);
427    procedure Set_Cunit_Entity     (U : Unit_Number_Type; E : Entity_Id);
428    procedure Set_Dynamic_Elab     (U : Unit_Number_Type; B : Boolean := True);
429    procedure Set_Error_Location   (U : Unit_Number_Type; W : Source_Ptr);
430    procedure Set_Fatal_Error      (U : Unit_Number_Type; B : Boolean := True);
431    procedure Set_Generate_Code    (U : Unit_Number_Type; B : Boolean := True);
432    procedure Set_Has_RACW         (U : Unit_Number_Type; B : Boolean := True);
433    procedure Set_Has_Allocator    (U : Unit_Number_Type; B : Boolean := True);
434    procedure Set_Is_Compiler_Unit (U : Unit_Number_Type; B : Boolean := True);
435    procedure Set_Ident_String     (U : Unit_Number_Type; N : Node_Id);
436    procedure Set_Loading          (U : Unit_Number_Type; B : Boolean := True);
437    procedure Set_Main_CPU         (U : Unit_Number_Type; P : Int);
438    procedure Set_Main_Priority    (U : Unit_Number_Type; P : Int);
439    procedure Set_OA_Setting       (U : Unit_Number_Type; C : Character);
440    procedure Set_Unit_Name        (U : Unit_Number_Type; N : Unit_Name_Type);
441    --  Set value of named field for given units table entry. Note that we
442    --  do not have an entry for each possible field, since some of the fields
443    --  can only be set by specialized interfaces (defined below).
444
445    function Version_Get (U : Unit_Number_Type) return Word_Hex_String;
446    --  Returns the version as a string with 8 hex digits (upper case letters)
447
448    function Last_Unit return Unit_Number_Type;
449    --  Unit number of last allocated unit
450
451    function Num_Units return Nat;
452    --  Number of units currently in unit table
453
454    procedure Remove_Unit (U : Unit_Number_Type);
455    --  Remove unit U from unit table. Currently this is effective only
456    --  if U is the last unit currently stored in the unit table.
457
458    function Entity_Is_In_Main_Unit (E : Entity_Id) return Boolean;
459    --  Returns True if the entity E is declared in the main unit, or, in
460    --  its corresponding spec, or one of its subunits. Entities declared
461    --  within generic instantiations return True if the instantiation is
462    --  itself "in the main unit" by this definition. Otherwise False.
463
464    function Get_Source_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type;
465    pragma Inline (Get_Source_Unit);
466    function Get_Source_Unit (S : Source_Ptr) return Unit_Number_Type;
467    --  Return unit number of file identified by given source pointer value.
468    --  This call must always succeed, since any valid source pointer value
469    --  belongs to some previously loaded module. If the given source pointer
470    --  value is within an instantiation, this function returns the unit number
471    --  of the template, i.e. the unit containing the source code corresponding
472    --  to the given Source_Ptr value. The version taking a Node_Id argument, N,
473    --  simply applies the function to Sloc (N).
474
475    function Get_Code_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type;
476    pragma Inline (Get_Code_Unit);
477    function Get_Code_Unit (S : Source_Ptr) return Unit_Number_Type;
478    --  This is like Get_Source_Unit, except that in the instantiation case,
479    --  it uses the location of the top level instantiation, rather than the
480    --  template, so it returns the unit number containing the code that
481    --  corresponds to the node N, or the source location S.
482
483    function In_Same_Source_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
484    pragma Inline (In_Same_Source_Unit);
485    --  Determines if the two nodes or entities N1 and N2 are in the same
486    --  source unit, the criterion being that Get_Source_Unit yields the
487    --  same value for each argument.
488
489    function In_Same_Code_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
490    pragma Inline (In_Same_Code_Unit);
491    --  Determines if the two nodes or entities N1 and N2 are in the same
492    --  code unit, the criterion being that Get_Code_Unit yields the same
493    --  value for each argument.
494
495    function In_Same_Extended_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
496    pragma Inline (In_Same_Extended_Unit);
497    --  Determines if two nodes or entities N1 and N2 are in the same
498    --  extended unit, where an extended unit is defined as a unit and all
499    --  its subunits (considered recursively, i.e. subunits of subunits are
500    --  included). Returns true if S1 and S2 are in the same extended unit
501    --  and False otherwise.
502
503    function In_Same_Extended_Unit (S1, S2 : Source_Ptr) return Boolean;
504    pragma Inline (In_Same_Extended_Unit);
505    --  Determines if the two source locations S1 and S2 are in the same
506    --  extended unit, where an extended unit is defined as a unit and all
507    --  its subunits (considered recursively, i.e. subunits of subunits are
508    --  included). Returns true if S1 and S2 are in the same extended unit
509    --  and False otherwise.
510
511    function In_Extended_Main_Code_Unit
512      (N : Node_Or_Entity_Id) return Boolean;
513    --  Return True if the node is in the generated code of the extended main
514    --  unit, defined as the main unit, its specification (if any), and all
515    --  its subunits (considered recursively). Units for which this enquiry
516    --  returns True are those for which code will be generated. Nodes from
517    --  instantiations are included in the extended main unit for this call.
518    --  If the main unit is itself a subunit, then the extended main unit
519    --  includes its parent unit, and the parent unit spec if it is separate.
520
521    function In_Extended_Main_Code_Unit (Loc : Source_Ptr) return Boolean;
522    --  Same function as above, but argument is a source pointer rather
523    --  than a node.
524
525    function In_Extended_Main_Source_Unit
526      (N : Node_Or_Entity_Id) return Boolean;
527    --  Return True if the node is in the source text of the extended main
528    --  unit, defined as the main unit, its specification (if any), and all
529    --  its subunits (considered recursively). Units for which this enquiry
530    --  returns True are those for which code will be generated. This differs
531    --  from In_Extended_Main_Code_Unit only in that instantiations are not
532    --  included for the purposes of this call. If the main unit is itself
533    --  a subunit, then the extended main unit includes its parent unit,
534    --  and the parent unit spec if it is separate.
535
536    function In_Extended_Main_Source_Unit (Loc : Source_Ptr) return Boolean;
537    --  Same function as above, but argument is a source pointer
538
539    function In_Predefined_Unit (N : Node_Or_Entity_Id) return Boolean;
540    --  Returns True if the given node or entity appears within the source text
541    --  of a predefined unit (i.e. within Ada, Interfaces, System or within one
542    --  of the descendent packages of one of these three packages).
543
544    function In_Predefined_Unit (S : Source_Ptr) return Boolean;
545    --  Same function as above but argument is a source pointer
546
547    function Earlier_In_Extended_Unit (S1, S2 : Source_Ptr) return Boolean;
548    --  Given two Sloc values for which In_Same_Extended_Unit is true, determine
549    --  if S1 appears before S2. Returns True if S1 appears before S2, and False
550    --  otherwise. The result is undefined if S1 and S2 are not in the same
551    --  extended unit. Note: this routine will not give reliable results if
552    --  called after Sprint has been called with -gnatD set.
553
554    function Compilation_Switches_Last return Nat;
555    --  Return the count of stored compilation switches
556
557    function Get_Compilation_Switch (N : Pos) return String_Ptr;
558    --  Return the Nth stored compilation switch, or null if less than N
559    --  switches have been stored. Used by ASIS and back ends written in Ada.
560
561    function Get_Cunit_Unit_Number (N : Node_Id) return Unit_Number_Type;
562    --  Return unit number of the unit whose N_Compilation_Unit node is the
563    --  one passed as an argument. This must always succeed since the node
564    --  could not have been built without making a unit table entry.
565
566    function Get_Cunit_Entity_Unit_Number
567      (E : Entity_Id) return Unit_Number_Type;
568    --  Return unit number of the unit whose compilation unit spec entity is
569    --  the one passed as an argument. This must always succeed since the
570    --  entity could not have been built without making a unit table entry.
571
572    function Increment_Serial_Number return Nat;
573    --  Increment Serial_Number field for current unit, and return the
574    --  incremented value.
575
576    procedure Synchronize_Serial_Number;
577    --  This function increments the Serial_Number field for the current unit
578    --  but does not return the incremented value. This is used when there
579    --  is a situation where one path of control increments a serial number
580    --  (using Increment_Serial_Number), and the other path does not and it is
581    --  important to keep the serial numbers synchronized in the two cases (e.g.
582    --  when the references in a package and a client must be kept consistent).
583
584    procedure Replace_Linker_Option_String
585      (S            : String_Id;
586       Match_String : String);
587    --  Replace an existing Linker_Option if the prefix Match_String matches,
588    --  otherwise call Store_Linker_Option_String.
589
590    procedure Store_Compilation_Switch (Switch : String);
591    --  Called to register a compilation switch, either front-end or back-end,
592    --  which may influence the generated output file(s). Switch is the text of
593    --  the switch to store (except that -fRTS gets changed back to --RTS).
594
595    procedure Enable_Switch_Storing;
596    --  Enable registration of switches by Store_Compilation_Switch. Used to
597    --  avoid registering switches added automatically by the gcc driver at the
598    --  beginning of the command line.
599
600    procedure Disable_Switch_Storing;
601    --  Disable registration of switches by Store_Compilation_Switch. Used to
602    --  avoid registering switches added automatically by the gcc driver at the
603    --  end of the command line.
604
605    procedure Store_Linker_Option_String (S : String_Id);
606    --  This procedure is called to register the string from a pragma
607    --  Linker_Option. The argument is the Id of the string to register.
608
609    procedure Store_Note (N : Node_Id);
610    --  This procedure is called to register a pragma N for which a notes
611    --  entry is required.
612
613    procedure Initialize;
614    --  Initialize internal tables
615
616    procedure Lock;
617    --  Lock internal tables before calling back end
618
619    procedure Unlock;
620    --  Unlock internal tables, in cases where the back end needs to modify them
621
622    procedure Tree_Read;
623    --  Initializes internal tables from current tree file using the relevant
624    --  Table.Tree_Read routines.
625
626    procedure Tree_Write;
627    --  Writes out internal tables to current tree file using the relevant
628    --  Table.Tree_Write routines.
629
630    function Is_Loaded (Uname : Unit_Name_Type) return Boolean;
631    --  Determines if unit with given name is already loaded, i.e. there is
632    --  already an entry in the file table with this unit name for which the
633    --  corresponding file was found and parsed. Note that the Fatal_Error flag
634    --  of this entry must be checked before proceeding with further processing.
635
636    procedure Version_Referenced (S : String_Id);
637    --  This routine is called from Exp_Attr to register the use of a Version
638    --  or Body_Version attribute. The argument is the external name used to
639    --  access the version string.
640
641    procedure List (File_Names_Only : Boolean := False);
642    --  Lists units in active library (i.e. generates output consisting of a
643    --  sorted listing of the units represented in File table, except for the
644    --  main unit). If File_Names_Only is set to True, then the list includes
645    --  only file names, and no other information. Otherwise the unit name and
646    --  time stamp are also output. File_Names_Only also restricts the list to
647    --  exclude any predefined files.
648
649    function Generic_May_Lack_ALI (Sfile : File_Name_Type) return Boolean;
650    --  Generic units must be separately compiled. Since we always use
651    --  macro substitution for generics, the resulting object file is a dummy
652    --  one with no code, but the ALI file has the normal form, and we need
653    --  this ALI file so that the binder can work out a correct order of
654    --  elaboration.
655
656    --  However, ancient versions of GNAT used to not generate code or ALI
657    --  files for generic units, and this would yield complex order of
658    --  elaboration issues. These were fixed in GNAT 3.10. The support for not
659    --  compiling language-defined library generics was retained nonetheless
660    --  to facilitate bootstrap. Specifically, it is convenient to have
661    --  the same list of files to be compiled for all stages. So, if the
662    --  bootstrap compiler does not generate code for a given file, then
663    --  the stage1 compiler (and binder) also must deal with the case of
664    --  that file not being compiled. The predicate Generic_May_Lack_ALI is
665    --  True for those generic units for which missing ALI files are allowed.
666
667 private
668    pragma Inline (Cunit);
669    pragma Inline (Cunit_Entity);
670    pragma Inline (Dependency_Num);
671    pragma Inline (Fatal_Error);
672    pragma Inline (Generate_Code);
673    pragma Inline (Has_Allocator);
674    pragma Inline (Has_RACW);
675    pragma Inline (Is_Compiler_Unit);
676    pragma Inline (Increment_Serial_Number);
677    pragma Inline (Loading);
678    pragma Inline (Main_CPU);
679    pragma Inline (Main_Priority);
680    pragma Inline (Munit_Index);
681    pragma Inline (OA_Setting);
682    pragma Inline (Set_Cunit);
683    pragma Inline (Set_Cunit_Entity);
684    pragma Inline (Set_Fatal_Error);
685    pragma Inline (Set_Generate_Code);
686    pragma Inline (Set_Has_Allocator);
687    pragma Inline (Set_Has_RACW);
688    pragma Inline (Set_Loading);
689    pragma Inline (Set_Main_CPU);
690    pragma Inline (Set_Main_Priority);
691    pragma Inline (Set_OA_Setting);
692    pragma Inline (Set_Unit_Name);
693    pragma Inline (Source_Index);
694    pragma Inline (Unit_File_Name);
695    pragma Inline (Unit_Name);
696
697    type Unit_Record is record
698       Unit_File_Name   : File_Name_Type;
699       Unit_Name        : Unit_Name_Type;
700       Munit_Index      : Nat;
701       Expected_Unit    : Unit_Name_Type;
702       Source_Index     : Source_File_Index;
703       Cunit            : Node_Id;
704       Cunit_Entity     : Entity_Id;
705       Dependency_Num   : Int;
706       Ident_String     : Node_Id;
707       Main_Priority    : Int;
708       Main_CPU         : Int;
709       Serial_Number    : Nat;
710       Version          : Word;
711       Error_Location   : Source_Ptr;
712       Fatal_Error      : Boolean;
713       Generate_Code    : Boolean;
714       Has_RACW         : Boolean;
715       Is_Compiler_Unit : Boolean;
716       Dynamic_Elab     : Boolean;
717       Loading          : Boolean;
718       Has_Allocator    : Boolean;
719       OA_Setting       : Character;
720    end record;
721
722    --  The following representation clause ensures that the above record
723    --  has no holes. We do this so that when instances of this record are
724    --  written by Tree_Gen, we do not write uninitialized values to the file.
725
726    for Unit_Record use record
727       Unit_File_Name   at  0 range 0 .. 31;
728       Unit_Name        at  4 range 0 .. 31;
729       Munit_Index      at  8 range 0 .. 31;
730       Expected_Unit    at 12 range 0 .. 31;
731       Source_Index     at 16 range 0 .. 31;
732       Cunit            at 20 range 0 .. 31;
733       Cunit_Entity     at 24 range 0 .. 31;
734       Dependency_Num   at 28 range 0 .. 31;
735       Ident_String     at 32 range 0 .. 31;
736       Main_Priority    at 36 range 0 .. 31;
737       Main_CPU         at 40 range 0 .. 31;
738       Serial_Number    at 44 range 0 .. 31;
739       Version          at 48 range 0 .. 31;
740       Error_Location   at 52 range 0 .. 31;
741       Fatal_Error      at 56 range 0 ..  7;
742       Generate_Code    at 57 range 0 ..  7;
743       Has_RACW         at 58 range 0 ..  7;
744       Dynamic_Elab     at 59 range 0 ..  7;
745       Is_Compiler_Unit at 60 range 0 ..  7;
746       OA_Setting       at 61 range 0 ..  7;
747       Loading          at 62 range 0 ..  7;
748       Has_Allocator    at 63 range 0 ..  7;
749    end record;
750
751    for Unit_Record'Size use 64 * 8;
752    --  This ensures that we did not leave out any fields
753
754    package Units is new Table.Table (
755      Table_Component_Type => Unit_Record,
756      Table_Index_Type     => Unit_Number_Type,
757      Table_Low_Bound      => Main_Unit,
758      Table_Initial        => Alloc.Units_Initial,
759      Table_Increment      => Alloc.Units_Increment,
760      Table_Name           => "Units");
761
762    --  The following table stores strings from pragma Linker_Option lines
763
764    type Linker_Option_Entry is record
765       Option : String_Id;
766       --  The string for the linker option line
767
768       Unit : Unit_Number_Type;
769       --  The unit from which the linker option comes
770    end record;
771
772    package Linker_Option_Lines is new Table.Table (
773      Table_Component_Type => Linker_Option_Entry,
774      Table_Index_Type     => Integer,
775      Table_Low_Bound      => 1,
776      Table_Initial        => Alloc.Linker_Option_Lines_Initial,
777      Table_Increment      => Alloc.Linker_Option_Lines_Increment,
778      Table_Name           => "Linker_Option_Lines");
779
780    --  The following table stores references to pragmas that generate Notes
781
782    type Notes_Entry is record
783       Pragma_Node : Node_Id;
784       Unit        : Unit_Number_Type;
785    end record;
786
787    package Notes is new Table.Table (
788      Table_Component_Type => Notes_Entry,
789      Table_Index_Type     => Integer,
790      Table_Low_Bound      => 1,
791      Table_Initial        => Alloc.Notes_Initial,
792      Table_Increment      => Alloc.Notes_Increment,
793      Table_Name           => "Notes");
794
795    --  The following table records the compilation switches used to compile
796    --  the main unit. The table includes only switches. It excludes -o
797    --  switches as well as artifacts of the gcc/gnat1 interface such as
798    --  -quiet, -dumpbase, or -auxbase.
799
800    --  This table is set as part of the compiler argument scanning in
801    --  Back_End. It can also be reset in -gnatc mode from the data in an
802    --  existing ali file, and is read and written by the Tree_Read and
803    --  Tree_Write routines for ASIS.
804
805    package Compilation_Switches is new Table.Table (
806      Table_Component_Type => String_Ptr,
807      Table_Index_Type     => Nat,
808      Table_Low_Bound      => 1,
809      Table_Initial        => 30,
810      Table_Increment      => 100,
811      Table_Name           => "Compilation_Switches");
812
813    Load_Msg_Sloc : Source_Ptr;
814    --  Location for placing error messages (a token in the main source text)
815    --  This is set from Sloc (Enode) by Load only in the case where this Sloc
816    --  is in the main source file. This ensures that not found messages and
817    --  circular dependency messages reference the original with in this source.
818
819    type Unit_Ref_Table is array (Pos range <>) of Unit_Number_Type;
820    --  Type to hold list of indirect references to unit number table
821
822    type Load_Stack_Entry is record
823       Unit_Number : Unit_Number_Type;
824       With_Node   : Node_Id;
825    end record;
826
827    --  The Load_Stack table contains a list of unit numbers (indexes into the
828    --  unit table) of units being loaded on a single dependency chain, and a
829    --  flag to indicate whether this unit is loaded through a limited_with
830    --  clause. The First entry is the main unit. The second entry, if present
831    --  is a unit on which the first unit depends, etc. This stack is used to
832    --  generate error messages showing the dependency chain if a file is not
833    --  found, or whether a true circular dependency exists.  The Load_Unit
834    --  function makes an entry in this table when it is called, and removes
835    --  the entry just before it returns.
836
837    package Load_Stack is new Table.Table (
838      Table_Component_Type => Load_Stack_Entry,
839      Table_Index_Type     => Int,
840      Table_Low_Bound      => 0,
841      Table_Initial        => Alloc.Load_Stack_Initial,
842      Table_Increment      => Alloc.Load_Stack_Increment,
843      Table_Name           => "Load_Stack");
844
845    procedure Sort (Tbl : in out Unit_Ref_Table);
846    --  This procedure sorts the given unit reference table in order of
847    --  ascending unit names, where the ordering relation is as described
848    --  by the comparison routines provided by package Uname.
849
850    --  The Version_Ref table records Body_Version and Version attribute
851    --  references. The entries are simply the strings for the external
852    --  names that correspond to the referenced values.
853
854    package Version_Ref is new Table.Table (
855      Table_Component_Type => String_Id,
856      Table_Index_Type     => Nat,
857      Table_Low_Bound      => 1,
858      Table_Initial        => 20,
859      Table_Increment      => 100,
860      Table_Name           => "Version_Ref");
861
862 end Lib;