OSDN Git Service

PR target/50678
[pf3gnuchains/gcc-fork.git] / gcc / ada / erroutc.adb
1 ------------------------------------------------------------------------------
2 --                                                                          --
3 --                         GNAT COMPILER COMPONENTS                         --
4 --                                                                          --
5 --                              E R R O U T C                               --
6 --                                                                          --
7 --                                 B o d y                                  --
8 --                                                                          --
9 --          Copyright (C) 1992-2010, Free Software Foundation, Inc.         --
10 --                                                                          --
11 -- GNAT is free software;  you can  redistribute it  and/or modify it under --
12 -- terms of the  GNU General Public License as published  by the Free Soft- --
13 -- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14 -- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE.                                     --
17 --                                                                          --
18 -- You should have received a copy of the GNU General Public License along  --
19 -- with this program; see file COPYING3.  If not see                        --
20 -- <http://www.gnu.org/licenses/>.                                          --
21 --                                                                          --
22 -- GNAT was originally developed  by the GNAT team at  New York University. --
23 -- Extensive contributions were provided by Ada Core Technologies Inc.      --
24 --                                                                          --
25 ------------------------------------------------------------------------------
26
27 --  Warning! Error messages can be generated during Gigi processing by direct
28 --  calls to error message routines, so it is essential that the processing
29 --  in this body be consistent with the requirements for the Gigi processing
30 --  environment, and that in particular, no disallowed table expansion is
31 --  allowed to occur.
32
33 with Casing;   use Casing;
34 with Debug;    use Debug;
35 with Err_Vars; use Err_Vars;
36 with Namet;    use Namet;
37 with Opt;      use Opt;
38 with Output;   use Output;
39 with Sinput;   use Sinput;
40 with Snames;   use Snames;
41 with Targparm; use Targparm;
42 with Uintp;    use Uintp;
43
44 package body Erroutc is
45
46    ---------------
47    -- Add_Class --
48    ---------------
49
50    procedure Add_Class is
51    begin
52       if Class_Flag then
53          Class_Flag := False;
54          Set_Msg_Char (''');
55          Get_Name_String (Name_Class);
56          Set_Casing (Identifier_Casing (Flag_Source), Mixed_Case);
57          Set_Msg_Name_Buffer;
58       end if;
59    end Add_Class;
60
61    ----------------------
62    -- Buffer_Ends_With --
63    ----------------------
64
65    function Buffer_Ends_With (S : String) return Boolean is
66       Len : constant Natural := S'Length;
67    begin
68       return
69         Msglen > Len
70           and then Msg_Buffer (Msglen - Len) = ' '
71           and then Msg_Buffer (Msglen - Len + 1 .. Msglen) = S;
72    end Buffer_Ends_With;
73
74    -------------------
75    -- Buffer_Remove --
76    -------------------
77
78    procedure Buffer_Remove (S : String) is
79    begin
80       if Buffer_Ends_With (S) then
81          Msglen := Msglen - S'Length;
82       end if;
83    end Buffer_Remove;
84
85    -----------------------------
86    -- Check_Duplicate_Message --
87    -----------------------------
88
89    procedure Check_Duplicate_Message (M1, M2 : Error_Msg_Id) is
90       L1, L2 : Error_Msg_Id;
91       N1, N2 : Error_Msg_Id;
92
93       procedure Delete_Msg (Delete, Keep : Error_Msg_Id);
94       --  Called to delete message Delete, keeping message Keep. Marks
95       --  all messages of Delete with deleted flag set to True, and also
96       --  makes sure that for the error messages that are retained the
97       --  preferred message is the one retained (we prefer the shorter
98       --  one in the case where one has an Instance tag). Note that we
99       --  always know that Keep has at least as many continuations as
100       --  Delete (since we always delete the shorter sequence).
101
102       ----------------
103       -- Delete_Msg --
104       ----------------
105
106       procedure Delete_Msg (Delete, Keep : Error_Msg_Id) is
107          D, K : Error_Msg_Id;
108
109       begin
110          D := Delete;
111          K := Keep;
112
113          loop
114             Errors.Table (D).Deleted := True;
115
116             --  Adjust error message count
117
118             if Errors.Table (D).Warn or else Errors.Table (D).Style then
119                Warnings_Detected := Warnings_Detected - 1;
120
121             else
122                Total_Errors_Detected := Total_Errors_Detected - 1;
123
124                if Errors.Table (D).Serious then
125                   Serious_Errors_Detected := Serious_Errors_Detected - 1;
126                end if;
127             end if;
128
129             --  Substitute shorter of the two error messages
130
131             if Errors.Table (K).Text'Length > Errors.Table (D).Text'Length then
132                Errors.Table (K).Text := Errors.Table (D).Text;
133             end if;
134
135             D := Errors.Table (D).Next;
136             K := Errors.Table (K).Next;
137
138             if D = No_Error_Msg or else not Errors.Table (D).Msg_Cont then
139                return;
140             end if;
141          end loop;
142       end Delete_Msg;
143
144    --  Start of processing for Check_Duplicate_Message
145
146    begin
147       --  Both messages must be non-continuation messages and not deleted
148
149       if Errors.Table (M1).Msg_Cont
150         or else Errors.Table (M2).Msg_Cont
151         or else Errors.Table (M1).Deleted
152         or else Errors.Table (M2).Deleted
153       then
154          return;
155       end if;
156
157       --  Definitely not equal if message text does not match
158
159       if not Same_Error (M1, M2) then
160          return;
161       end if;
162
163       --  Same text. See if all continuations are also identical
164
165       L1 := M1;
166       L2 := M2;
167
168       loop
169          N1 := Errors.Table (L1).Next;
170          N2 := Errors.Table (L2).Next;
171
172          --  If M1 continuations have run out, we delete M1, either the
173          --  messages have the same number of continuations, or M2 has
174          --  more and we prefer the one with more anyway.
175
176          if N1 = No_Error_Msg or else not Errors.Table (N1).Msg_Cont then
177             Delete_Msg (M1, M2);
178             return;
179
180          --  If M2 continuations have run out, we delete M2
181
182          elsif N2 = No_Error_Msg or else not Errors.Table (N2).Msg_Cont then
183             Delete_Msg (M2, M1);
184             return;
185
186          --  Otherwise see if continuations are the same, if not, keep both
187          --  sequences, a curious case, but better to keep everything!
188
189          elsif not Same_Error (N1, N2) then
190             return;
191
192          --  If continuations are the same, continue scan
193
194          else
195             L1 := N1;
196             L2 := N2;
197          end if;
198       end loop;
199    end Check_Duplicate_Message;
200
201    ------------------------
202    -- Compilation_Errors --
203    ------------------------
204
205    function Compilation_Errors return Boolean is
206    begin
207       return Total_Errors_Detected /= 0
208         or else (Warnings_Detected /= 0
209                   and then Warning_Mode = Treat_As_Error);
210    end Compilation_Errors;
211
212    ------------------
213    -- Debug_Output --
214    ------------------
215
216    procedure Debug_Output (N : Node_Id) is
217    begin
218       if Debug_Flag_1 then
219          Write_Str ("*** following error message posted on node id = #");
220          Write_Int (Int (N));
221          Write_Str (" ***");
222          Write_Eol;
223       end if;
224    end Debug_Output;
225
226    ----------
227    -- dmsg --
228    ----------
229
230    procedure dmsg (Id : Error_Msg_Id) is
231       E : Error_Msg_Object renames Errors.Table (Id);
232
233    begin
234       w ("Dumping error message, Id = ", Int (Id));
235       w ("  Text     = ", E.Text.all);
236       w ("  Next     = ", Int (E.Next));
237       w ("  Sfile    = ", Int (E.Sfile));
238
239       Write_Str
240         ("  Sptr     = ");
241       Write_Location (E.Sptr);
242       Write_Eol;
243
244       Write_Str
245         ("  Optr     = ");
246       Write_Location (E.Optr);
247       Write_Eol;
248
249       w ("  Line     = ", Int (E.Line));
250       w ("  Col      = ", Int (E.Col));
251       w ("  Warn     = ", E.Warn);
252       w ("  Style    = ", E.Style);
253       w ("  Serious  = ", E.Serious);
254       w ("  Uncond   = ", E.Uncond);
255       w ("  Msg_Cont = ", E.Msg_Cont);
256       w ("  Deleted  = ", E.Deleted);
257
258       Write_Eol;
259    end dmsg;
260
261    ------------------
262    -- Get_Location --
263    ------------------
264
265    function Get_Location (E : Error_Msg_Id) return Source_Ptr is
266    begin
267       return Errors.Table (E).Sptr;
268    end Get_Location;
269
270    ----------------
271    -- Get_Msg_Id --
272    ----------------
273
274    function Get_Msg_Id return Error_Msg_Id is
275    begin
276       return Cur_Msg;
277    end Get_Msg_Id;
278
279    -----------------------
280    -- Output_Error_Msgs --
281    -----------------------
282
283    procedure Output_Error_Msgs (E : in out Error_Msg_Id) is
284       P : Source_Ptr;
285       T : Error_Msg_Id;
286       S : Error_Msg_Id;
287
288       Flag_Num   : Pos;
289       Mult_Flags : Boolean := False;
290
291    begin
292       S := E;
293
294       --  Skip deleted messages at start
295
296       if Errors.Table (S).Deleted then
297          Set_Next_Non_Deleted_Msg (S);
298       end if;
299
300       --  Figure out if we will place more than one error flag on this line
301
302       T := S;
303       while T /= No_Error_Msg
304         and then Errors.Table (T).Line = Errors.Table (E).Line
305         and then Errors.Table (T).Sfile = Errors.Table (E).Sfile
306       loop
307          if Errors.Table (T).Sptr > Errors.Table (E).Sptr then
308             Mult_Flags := True;
309          end if;
310
311          Set_Next_Non_Deleted_Msg (T);
312       end loop;
313
314       --  Output the error flags. The circuit here makes sure that the tab
315       --  characters in the original line are properly accounted for. The
316       --  eight blanks at the start are to match the line number.
317
318       if not Debug_Flag_2 then
319          Write_Str ("        ");
320          P := Line_Start (Errors.Table (E).Sptr);
321          Flag_Num := 1;
322
323          --  Loop through error messages for this line to place flags
324
325          T := S;
326          while T /= No_Error_Msg
327            and then Errors.Table (T).Line = Errors.Table (E).Line
328            and then Errors.Table (T).Sfile = Errors.Table (E).Sfile
329          loop
330             --  Loop to output blanks till current flag position
331
332             while P < Errors.Table (T).Sptr loop
333                if Source_Text (Errors.Table (T).Sfile) (P) = ASCII.HT then
334                   Write_Char (ASCII.HT);
335                else
336                   Write_Char (' ');
337                end if;
338
339                P := P + 1;
340             end loop;
341
342             --  Output flag (unless already output, this happens if more
343             --  than one error message occurs at the same flag position).
344
345             if P = Errors.Table (T).Sptr then
346                if (Flag_Num = 1 and then not Mult_Flags)
347                  or else Flag_Num > 9
348                then
349                   Write_Char ('|');
350                else
351                   Write_Char (Character'Val (Character'Pos ('0') + Flag_Num));
352                end if;
353
354                P := P + 1;
355             end if;
356
357             Set_Next_Non_Deleted_Msg (T);
358             Flag_Num := Flag_Num + 1;
359          end loop;
360
361          Write_Eol;
362       end if;
363
364       --  Now output the error messages
365
366       T := S;
367       while T /= No_Error_Msg
368         and then Errors.Table (T).Line = Errors.Table (E).Line
369         and then Errors.Table (T).Sfile = Errors.Table (E).Sfile
370       loop
371          Write_Str ("        >>> ");
372          Output_Msg_Text (T);
373
374          if Debug_Flag_2 then
375             while Column < 74 loop
376                Write_Char (' ');
377             end loop;
378
379             Write_Str (" <<<");
380          end if;
381
382          Write_Eol;
383          Set_Next_Non_Deleted_Msg (T);
384       end loop;
385
386       E := T;
387    end Output_Error_Msgs;
388
389    ------------------------
390    -- Output_Line_Number --
391    ------------------------
392
393    procedure Output_Line_Number (L : Logical_Line_Number) is
394       D     : Int;       -- next digit
395       C     : Character; -- next character
396       Z     : Boolean;   -- flag for zero suppress
397       N, M  : Int;       -- temporaries
398
399    begin
400       if L = No_Line_Number then
401          Write_Str ("        ");
402
403       else
404          Z := False;
405          N := Int (L);
406
407          M := 100_000;
408          while M /= 0 loop
409             D := Int (N / M);
410             N := N rem M;
411             M := M / 10;
412
413             if D = 0 then
414                if Z then
415                   C := '0';
416                else
417                   C := ' ';
418                end if;
419             else
420                Z := True;
421                C := Character'Val (D + 48);
422             end if;
423
424             Write_Char (C);
425          end loop;
426
427          Write_Str (". ");
428       end if;
429    end Output_Line_Number;
430
431    ---------------------
432    -- Output_Msg_Text --
433    ---------------------
434
435    procedure Output_Msg_Text (E : Error_Msg_Id) is
436       Offs : constant Nat := Column - 1;
437       --  Offset to start of message, used for continuations
438
439       Max : Integer;
440       --  Maximum characters to output on next line
441
442       Length : Nat;
443       --  Maximum total length of lines
444
445       Txt   : constant String_Ptr := Errors.Table (E).Text;
446       Len   : constant Natural    := Txt'Length;
447       Ptr   : Natural;
448       Split : Natural;
449       Start : Natural;
450
451    begin
452       if Error_Msg_Line_Length = 0 then
453          Length := Nat'Last;
454       else
455          Length := Error_Msg_Line_Length;
456       end if;
457
458       Max := Integer (Length - Column + 1);
459
460       --  For warning message, add "warning: " unless msg starts with "info: "
461
462       if Errors.Table (E).Warn then
463          if Len < 6 or else Txt (Txt'First .. Txt'First + 5) /= "info: " then
464             Write_Str ("warning: ");
465             Max := Max - 9;
466          end if;
467
468       --  No prefix needed for style message, since "(style)" is there already
469
470       elsif Errors.Table (E).Style then
471          null;
472
473       --  All other cases, add "error: "
474
475       elsif Opt.Unique_Error_Tag then
476          Write_Str ("error: ");
477          Max := Max - 7;
478       end if;
479
480       --  Here we have to split the message up into multiple lines
481
482       Ptr := 1;
483       loop
484          --  Make sure we do not have ludicrously small line
485
486          Max := Integer'Max (Max, 20);
487
488          --  If remaining text fits, output it respecting LF and we are done
489
490          if Len - Ptr < Max then
491             for J in Ptr .. Len loop
492                if Txt (J) = ASCII.LF then
493                   Write_Eol;
494                   Write_Spaces (Offs);
495                else
496                   Write_Char (Txt (J));
497                end if;
498             end loop;
499
500             return;
501
502             --  Line does not fit
503
504          else
505             Start := Ptr;
506
507             --  First scan forward looking for a hard end of line
508
509             for Scan in Ptr .. Ptr + Max - 1 loop
510                if Txt (Scan) = ASCII.LF then
511                   Split := Scan - 1;
512                   Ptr := Scan + 1;
513                   goto Continue;
514                end if;
515             end loop;
516
517             --  Otherwise scan backwards looking for a space
518
519             for Scan in reverse Ptr .. Ptr + Max - 1 loop
520                if Txt (Scan) = ' ' then
521                   Split := Scan - 1;
522                   Ptr := Scan + 1;
523                   goto Continue;
524                end if;
525             end loop;
526
527             --  If we fall through, no space, so split line arbitrarily
528
529             Split := Ptr + Max - 1;
530             Ptr := Split + 1;
531          end if;
532
533          <<Continue>>
534          if Start <= Split then
535             Write_Line (Txt (Start .. Split));
536             Write_Spaces (Offs);
537          end if;
538
539          Max := Integer (Length - Column + 1);
540       end loop;
541    end Output_Msg_Text;
542
543    --------------------
544    -- Purge_Messages --
545    --------------------
546
547    procedure Purge_Messages (From : Source_Ptr; To : Source_Ptr) is
548       E : Error_Msg_Id;
549
550       function To_Be_Purged (E : Error_Msg_Id) return Boolean;
551       --  Returns True for a message that is to be purged. Also adjusts
552       --  error counts appropriately.
553
554       ------------------
555       -- To_Be_Purged --
556       ------------------
557
558       function To_Be_Purged (E : Error_Msg_Id) return Boolean is
559       begin
560          if E /= No_Error_Msg
561            and then Errors.Table (E).Sptr > From
562            and then Errors.Table (E).Sptr < To
563          then
564             if Errors.Table (E).Warn or else Errors.Table (E).Style then
565                Warnings_Detected := Warnings_Detected - 1;
566
567             else
568                Total_Errors_Detected := Total_Errors_Detected - 1;
569
570                if Errors.Table (E).Serious then
571                   Serious_Errors_Detected := Serious_Errors_Detected - 1;
572                end if;
573             end if;
574
575             return True;
576
577          else
578             return False;
579          end if;
580       end To_Be_Purged;
581
582    --  Start of processing for Purge_Messages
583
584    begin
585       while To_Be_Purged (First_Error_Msg) loop
586          First_Error_Msg := Errors.Table (First_Error_Msg).Next;
587       end loop;
588
589       E := First_Error_Msg;
590       while E /= No_Error_Msg loop
591          while To_Be_Purged (Errors.Table (E).Next) loop
592             Errors.Table (E).Next :=
593               Errors.Table (Errors.Table (E).Next).Next;
594          end loop;
595
596          E := Errors.Table (E).Next;
597       end loop;
598    end Purge_Messages;
599
600    ----------------
601    -- Same_Error --
602    ----------------
603
604    function Same_Error (M1, M2 : Error_Msg_Id) return Boolean is
605       Msg1 : constant String_Ptr := Errors.Table (M1).Text;
606       Msg2 : constant String_Ptr := Errors.Table (M2).Text;
607
608       Msg2_Len : constant Integer := Msg2'Length;
609       Msg1_Len : constant Integer := Msg1'Length;
610
611    begin
612       return
613         Msg1.all = Msg2.all
614           or else
615             (Msg1_Len - 10 > Msg2_Len
616                and then
617              Msg2.all = Msg1.all (1 .. Msg2_Len)
618                and then
619              Msg1 (Msg2_Len + 1 .. Msg2_Len + 10) = ", instance")
620           or else
621             (Msg2_Len - 10 > Msg1_Len
622                and then
623              Msg1.all = Msg2.all (1 .. Msg1_Len)
624                and then
625              Msg2 (Msg1_Len + 1 .. Msg1_Len + 10) = ", instance");
626    end Same_Error;
627
628    -------------------
629    -- Set_Msg_Blank --
630    -------------------
631
632    procedure Set_Msg_Blank is
633    begin
634       if Msglen > 0
635         and then Msg_Buffer (Msglen) /= ' '
636         and then Msg_Buffer (Msglen) /= '('
637         and then Msg_Buffer (Msglen) /= '-'
638         and then not Manual_Quote_Mode
639       then
640          Set_Msg_Char (' ');
641       end if;
642    end Set_Msg_Blank;
643
644    -------------------------------
645    -- Set_Msg_Blank_Conditional --
646    -------------------------------
647
648    procedure Set_Msg_Blank_Conditional is
649    begin
650       if Msglen > 0
651         and then Msg_Buffer (Msglen) /= ' '
652         and then Msg_Buffer (Msglen) /= '('
653         and then Msg_Buffer (Msglen) /= '"'
654         and then not Manual_Quote_Mode
655       then
656          Set_Msg_Char (' ');
657       end if;
658    end Set_Msg_Blank_Conditional;
659
660    ------------------
661    -- Set_Msg_Char --
662    ------------------
663
664    procedure Set_Msg_Char (C : Character) is
665    begin
666
667       --  The check for message buffer overflow is needed to deal with cases
668       --  where insertions get too long (in particular a child unit name can
669       --  be very long).
670
671       if Msglen < Max_Msg_Length then
672          Msglen := Msglen + 1;
673          Msg_Buffer (Msglen) := C;
674       end if;
675    end Set_Msg_Char;
676
677    ---------------------------------
678    -- Set_Msg_Insertion_File_Name --
679    ---------------------------------
680
681    procedure Set_Msg_Insertion_File_Name is
682    begin
683       if Error_Msg_File_1 = No_File then
684          null;
685
686       elsif Error_Msg_File_1 = Error_File_Name then
687          Set_Msg_Blank;
688          Set_Msg_Str ("<error>");
689
690       else
691          Set_Msg_Blank;
692          Get_Name_String (Error_Msg_File_1);
693          Set_Msg_Quote;
694          Set_Msg_Name_Buffer;
695          Set_Msg_Quote;
696       end if;
697
698       --  The following assignments ensure that the second and third {
699       --  insertion characters will correspond to the Error_Msg_File_2 and
700       --  Error_Msg_File_3 values and We suppress possible validity checks in
701       --  case operating in -gnatVa mode, and Error_Msg_File_2 or
702       --  Error_Msg_File_3 is not needed and has not been set.
703
704       declare
705          pragma Suppress (Range_Check);
706       begin
707          Error_Msg_File_1 := Error_Msg_File_2;
708          Error_Msg_File_2 := Error_Msg_File_3;
709       end;
710    end Set_Msg_Insertion_File_Name;
711
712    -----------------------------------
713    -- Set_Msg_Insertion_Line_Number --
714    -----------------------------------
715
716    procedure Set_Msg_Insertion_Line_Number (Loc, Flag : Source_Ptr) is
717       Sindex_Loc  : Source_File_Index;
718       Sindex_Flag : Source_File_Index;
719
720       procedure Set_At;
721       --  Outputs "at " unless last characters in buffer are " from ". Certain
722       --  messages read better with from than at.
723
724       ------------
725       -- Set_At --
726       ------------
727
728       procedure Set_At is
729       begin
730          if Msglen < 6
731            or else Msg_Buffer (Msglen - 5 .. Msglen) /= " from "
732          then
733             Set_Msg_Str ("at ");
734          end if;
735       end Set_At;
736
737    --  Start of processing for Set_Msg_Insertion_Line_Number
738
739    begin
740       Set_Msg_Blank;
741
742       if Loc = No_Location then
743          Set_At;
744          Set_Msg_Str ("unknown location");
745
746       elsif Loc = System_Location then
747          Set_Msg_Str ("in package System");
748          Set_Msg_Insertion_Run_Time_Name;
749
750       elsif Loc = Standard_Location then
751          Set_Msg_Str ("in package Standard");
752
753       elsif Loc = Standard_ASCII_Location then
754          Set_Msg_Str ("in package Standard.ASCII");
755
756       else
757          --  Add "at file-name:" if reference is to other than the source
758          --  file in which the error message is placed. Note that we check
759          --  full file names, rather than just the source indexes, to
760          --  deal with generic instantiations from the current file.
761
762          Sindex_Loc  := Get_Source_File_Index (Loc);
763          Sindex_Flag := Get_Source_File_Index (Flag);
764
765          if Full_File_Name (Sindex_Loc) /= Full_File_Name (Sindex_Flag) then
766             Set_At;
767             Get_Name_String
768               (Reference_Name (Get_Source_File_Index (Loc)));
769             Set_Msg_Name_Buffer;
770             Set_Msg_Char (':');
771
772          --  If in current file, add text "at line "
773
774          else
775             Set_At;
776             Set_Msg_Str ("line ");
777          end if;
778
779          --  Output line number for reference
780
781          Set_Msg_Int (Int (Get_Logical_Line_Number (Loc)));
782
783          --  Deal with the instantiation case. We may have a reference to,
784          --  e.g. a type, that is declared within a generic template, and
785          --  what we are really referring to is the occurrence in an instance.
786          --  In this case, the line number of the instantiation is also of
787          --  interest, and we add a notation:
788
789          --    , instance at xxx
790
791          --  where xxx is a line number output using this same routine (and
792          --  the recursion can go further if the instantiation is itself in
793          --  a generic template).
794
795          --  The flag location passed to us in this situation is indeed the
796          --  line number within the template, but as described in Sinput.L
797          --  (file sinput-l.ads, section "Handling Generic Instantiations")
798          --  we can retrieve the location of the instantiation itself from
799          --  this flag location value.
800
801          --  Note: this processing is suppressed if Suppress_Instance_Location
802          --  is set True. This is used to prevent redundant annotations of the
803          --  location of the instantiation in the case where we are placing
804          --  the messages on the instantiation in any case.
805
806          if Instantiation (Sindex_Loc) /= No_Location
807            and then not Suppress_Instance_Location
808          then
809             Set_Msg_Str (", instance ");
810             Set_Msg_Insertion_Line_Number (Instantiation (Sindex_Loc), Flag);
811          end if;
812       end if;
813    end Set_Msg_Insertion_Line_Number;
814
815    ----------------------------
816    -- Set_Msg_Insertion_Name --
817    ----------------------------
818
819    procedure Set_Msg_Insertion_Name is
820    begin
821       if Error_Msg_Name_1 = No_Name then
822          null;
823
824       elsif Error_Msg_Name_1 = Error_Name then
825          Set_Msg_Blank;
826          Set_Msg_Str ("<error>");
827
828       else
829          Set_Msg_Blank_Conditional;
830          Get_Unqualified_Decoded_Name_String (Error_Msg_Name_1);
831
832          --  Remove %s or %b at end. These come from unit names. If the
833          --  caller wanted the (unit) or (body), then they would have used
834          --  the $ insertion character. Certainly no error message should
835          --  ever have %b or %s explicitly occurring.
836
837          if Name_Len > 2
838            and then Name_Buffer (Name_Len - 1) = '%'
839            and then (Name_Buffer (Name_Len) = 'b'
840                        or else
841                      Name_Buffer (Name_Len) = 's')
842          then
843             Name_Len := Name_Len - 2;
844          end if;
845
846          --  Remove upper case letter at end, again, we should not be getting
847          --  such names, and what we hope is that the remainder makes sense.
848
849          if Name_Len > 1
850            and then Name_Buffer (Name_Len) in 'A' .. 'Z'
851          then
852             Name_Len := Name_Len - 1;
853          end if;
854
855          --  If operator name or character literal name, just print it as is
856          --  Also print as is if it ends in a right paren (case of x'val(nnn))
857
858          if Name_Buffer (1) = '"'
859            or else Name_Buffer (1) = '''
860            or else Name_Buffer (Name_Len) = ')'
861          then
862             Set_Msg_Name_Buffer;
863
864          --  Else output with surrounding quotes in proper casing mode
865
866          else
867             Set_Casing (Identifier_Casing (Flag_Source), Mixed_Case);
868             Set_Msg_Quote;
869             Set_Msg_Name_Buffer;
870             Set_Msg_Quote;
871          end if;
872       end if;
873
874       --  The following assignments ensure that the second and third percent
875       --  insertion characters will correspond to the Error_Msg_Name_2 and
876       --  Error_Msg_Name_3 as required. We suppress possible validity checks in
877       --  case operating in -gnatVa mode, and Error_Msg_Name_1/2 is not needed
878       --  and has not been set.
879
880       declare
881          pragma Suppress (Range_Check);
882       begin
883          Error_Msg_Name_1 := Error_Msg_Name_2;
884          Error_Msg_Name_2 := Error_Msg_Name_3;
885       end;
886    end Set_Msg_Insertion_Name;
887
888    ------------------------------------
889    -- Set_Msg_Insertion_Name_Literal --
890    ------------------------------------
891
892    procedure Set_Msg_Insertion_Name_Literal is
893    begin
894       if Error_Msg_Name_1 = No_Name then
895          null;
896
897       elsif Error_Msg_Name_1 = Error_Name then
898          Set_Msg_Blank;
899          Set_Msg_Str ("<error>");
900
901       else
902          Set_Msg_Blank;
903          Get_Name_String (Error_Msg_Name_1);
904          Set_Msg_Quote;
905          Set_Msg_Name_Buffer;
906          Set_Msg_Quote;
907       end if;
908
909       --  The following assignments ensure that the second and third % or %%
910       --  insertion characters will correspond to the Error_Msg_Name_2 and
911       --  Error_Msg_Name_3 values and We suppress possible validity checks in
912       --  case operating in -gnatVa mode, and Error_Msg_Name_2 or
913       --  Error_Msg_Name_3 is not needed and has not been set.
914
915       declare
916          pragma Suppress (Range_Check);
917       begin
918          Error_Msg_Name_1 := Error_Msg_Name_2;
919          Error_Msg_Name_2 := Error_Msg_Name_3;
920       end;
921    end Set_Msg_Insertion_Name_Literal;
922
923    -------------------------------------
924    -- Set_Msg_Insertion_Reserved_Name --
925    -------------------------------------
926
927    procedure Set_Msg_Insertion_Reserved_Name is
928    begin
929       Set_Msg_Blank_Conditional;
930       Get_Name_String (Error_Msg_Name_1);
931       Set_Msg_Quote;
932       Set_Casing (Keyword_Casing (Flag_Source), All_Lower_Case);
933       Set_Msg_Name_Buffer;
934       Set_Msg_Quote;
935    end Set_Msg_Insertion_Reserved_Name;
936
937    -------------------------------------
938    -- Set_Msg_Insertion_Reserved_Word --
939    -------------------------------------
940
941    procedure Set_Msg_Insertion_Reserved_Word
942      (Text : String;
943       J    : in out Integer)
944    is
945    begin
946       Set_Msg_Blank_Conditional;
947       Name_Len := 0;
948
949       while J <= Text'Last and then Text (J) in 'A' .. 'Z' loop
950          Add_Char_To_Name_Buffer (Text (J));
951          J := J + 1;
952       end loop;
953
954       --  Here is where we make the special exception for RM
955
956       if Name_Len = 2 and then Name_Buffer (1 .. 2) = "RM" then
957          Set_Msg_Name_Buffer;
958
959       --  Not RM: case appropriately and add surrounding quotes
960
961       else
962          Set_Casing (Keyword_Casing (Flag_Source), All_Lower_Case);
963          Set_Msg_Quote;
964          Set_Msg_Name_Buffer;
965          Set_Msg_Quote;
966       end if;
967    end Set_Msg_Insertion_Reserved_Word;
968
969    -------------------------------------
970    -- Set_Msg_Insertion_Run_Time_Name --
971    -------------------------------------
972
973    procedure Set_Msg_Insertion_Run_Time_Name is
974    begin
975       if Targparm.Run_Time_Name_On_Target /= No_Name then
976          Set_Msg_Blank_Conditional;
977          Set_Msg_Char ('(');
978          Get_Name_String (Targparm.Run_Time_Name_On_Target);
979          Set_Casing (Mixed_Case);
980          Set_Msg_Str (Name_Buffer (1 .. Name_Len));
981          Set_Msg_Char (')');
982       end if;
983    end Set_Msg_Insertion_Run_Time_Name;
984
985    ----------------------------
986    -- Set_Msg_Insertion_Uint --
987    ----------------------------
988
989    procedure Set_Msg_Insertion_Uint is
990    begin
991       Set_Msg_Blank;
992       UI_Image (Error_Msg_Uint_1);
993
994       for J in 1 .. UI_Image_Length loop
995          Set_Msg_Char (UI_Image_Buffer (J));
996       end loop;
997
998       --  The following assignment ensures that a second caret insertion
999       --  character will correspond to the Error_Msg_Uint_2 parameter. We
1000       --  suppress possible validity checks in case operating in -gnatVa mode,
1001       --  and Error_Msg_Uint_2 is not needed and has not been set.
1002
1003       declare
1004          pragma Suppress (Range_Check);
1005       begin
1006          Error_Msg_Uint_1 := Error_Msg_Uint_2;
1007       end;
1008    end Set_Msg_Insertion_Uint;
1009
1010    -----------------
1011    -- Set_Msg_Int --
1012    -----------------
1013
1014    procedure Set_Msg_Int (Line : Int) is
1015    begin
1016       if Line > 9 then
1017          Set_Msg_Int (Line / 10);
1018       end if;
1019
1020       Set_Msg_Char (Character'Val (Character'Pos ('0') + (Line rem 10)));
1021    end Set_Msg_Int;
1022
1023    -------------------------
1024    -- Set_Msg_Name_Buffer --
1025    -------------------------
1026
1027    procedure Set_Msg_Name_Buffer is
1028    begin
1029       for J in 1 .. Name_Len loop
1030          Set_Msg_Char (Name_Buffer (J));
1031       end loop;
1032    end Set_Msg_Name_Buffer;
1033
1034    -------------------
1035    -- Set_Msg_Quote --
1036    -------------------
1037
1038    procedure Set_Msg_Quote is
1039    begin
1040       if not Manual_Quote_Mode then
1041          Set_Msg_Char ('"');
1042       end if;
1043    end Set_Msg_Quote;
1044
1045    -----------------
1046    -- Set_Msg_Str --
1047    -----------------
1048
1049    procedure Set_Msg_Str (Text : String) is
1050    begin
1051       for J in Text'Range loop
1052          Set_Msg_Char (Text (J));
1053       end loop;
1054    end Set_Msg_Str;
1055
1056    ------------------------------
1057    -- Set_Next_Non_Deleted_Msg --
1058    ------------------------------
1059
1060    procedure Set_Next_Non_Deleted_Msg (E : in out Error_Msg_Id) is
1061    begin
1062       if E = No_Error_Msg then
1063          return;
1064
1065       else
1066          loop
1067             E := Errors.Table (E).Next;
1068             exit when E = No_Error_Msg or else not Errors.Table (E).Deleted;
1069          end loop;
1070       end if;
1071    end Set_Next_Non_Deleted_Msg;
1072
1073    ------------------------------
1074    -- Set_Specific_Warning_Off --
1075    ------------------------------
1076
1077    procedure Set_Specific_Warning_Off
1078      (Loc    : Source_Ptr;
1079       Msg    : String;
1080       Config : Boolean)
1081    is
1082    begin
1083       Specific_Warnings.Append
1084         ((Start      => Loc,
1085           Msg        => new String'(Msg),
1086           Stop       => Source_Last (Current_Source_File),
1087           Open       => True,
1088           Used       => False,
1089           Config     => Config));
1090    end Set_Specific_Warning_Off;
1091
1092    -----------------------------
1093    -- Set_Specific_Warning_On --
1094    -----------------------------
1095
1096    procedure Set_Specific_Warning_On
1097      (Loc : Source_Ptr;
1098       Msg : String;
1099       Err : out Boolean)
1100    is
1101    begin
1102       for J in 1 .. Specific_Warnings.Last loop
1103          declare
1104             SWE : Specific_Warning_Entry renames Specific_Warnings.Table (J);
1105          begin
1106             if Msg = SWE.Msg.all
1107               and then Loc > SWE.Start
1108               and then SWE.Open
1109               and then Get_Source_File_Index (SWE.Start) =
1110                        Get_Source_File_Index (Loc)
1111             then
1112                SWE.Stop := Loc;
1113                SWE.Open := False;
1114                Err := False;
1115
1116                --  If a config pragma is specifically cancelled, consider
1117                --  that it is no longer active as a configuration pragma.
1118
1119                SWE.Config := False;
1120                return;
1121             end if;
1122          end;
1123       end loop;
1124
1125       Err := True;
1126    end Set_Specific_Warning_On;
1127
1128    ---------------------------
1129    -- Set_Warnings_Mode_Off --
1130    ---------------------------
1131
1132    procedure Set_Warnings_Mode_Off (Loc : Source_Ptr) is
1133    begin
1134       --  Don't bother with entries from instantiation copies, since we
1135       --  will already have a copy in the template, which is what matters
1136
1137       if Instantiation (Get_Source_File_Index (Loc)) /= No_Location then
1138          return;
1139       end if;
1140
1141       --  If last entry in table already covers us, this is a redundant
1142       --  pragma Warnings (Off) and can be ignored. This also handles the
1143       --  case where all warnings are suppressed by command line switch.
1144
1145       if Warnings.Last >= Warnings.First
1146         and then Warnings.Table (Warnings.Last).Start <= Loc
1147         and then Loc <= Warnings.Table (Warnings.Last).Stop
1148       then
1149          return;
1150
1151       --  Otherwise establish a new entry, extending from the location of
1152       --  the pragma to the end of the current source file. This ending
1153       --  point will be adjusted by a subsequent pragma Warnings (On).
1154
1155       else
1156          Warnings.Increment_Last;
1157          Warnings.Table (Warnings.Last).Start := Loc;
1158          Warnings.Table (Warnings.Last).Stop :=
1159            Source_Last (Current_Source_File);
1160       end if;
1161    end Set_Warnings_Mode_Off;
1162
1163    --------------------------
1164    -- Set_Warnings_Mode_On --
1165    --------------------------
1166
1167    procedure Set_Warnings_Mode_On (Loc : Source_Ptr) is
1168    begin
1169       --  Don't bother with entries from instantiation copies, since we
1170       --  will already have a copy in the template, which is what matters
1171
1172       if Instantiation (Get_Source_File_Index (Loc)) /= No_Location then
1173          return;
1174       end if;
1175
1176       --  Nothing to do unless command line switch to suppress all warnings
1177       --  is off, and the last entry in the warnings table covers this
1178       --  pragma Warnings (On), in which case adjust the end point.
1179
1180       if (Warnings.Last >= Warnings.First
1181            and then Warnings.Table (Warnings.Last).Start <= Loc
1182            and then Loc <= Warnings.Table (Warnings.Last).Stop)
1183         and then Warning_Mode /= Suppress
1184       then
1185          Warnings.Table (Warnings.Last).Stop := Loc;
1186       end if;
1187    end Set_Warnings_Mode_On;
1188
1189    ------------------------------------
1190    -- Test_Style_Warning_Serious_Msg --
1191    ------------------------------------
1192
1193    procedure Test_Style_Warning_Serious_Msg (Msg : String) is
1194    begin
1195       if Msg (Msg'First) = '\' then
1196          return;
1197       end if;
1198
1199       Is_Serious_Error := True;
1200       Is_Warning_Msg   := False;
1201
1202       Is_Style_Msg :=
1203         (Msg'Length > 7 and then Msg (Msg'First .. Msg'First + 6) = "(style)");
1204
1205       if Is_Style_Msg then
1206          Is_Serious_Error := False;
1207       end if;
1208
1209       for J in Msg'Range loop
1210          if Msg (J) = '?'
1211            and then (J = Msg'First or else Msg (J - 1) /= ''')
1212          then
1213             Is_Warning_Msg := True;
1214
1215          elsif Msg (J) = '<'
1216            and then (J = Msg'First or else Msg (J - 1) /= ''')
1217          then
1218             Is_Warning_Msg := Error_Msg_Warn;
1219
1220          elsif Msg (J) = '|'
1221            and then (J = Msg'First or else Msg (J - 1) /= ''')
1222          then
1223             Is_Serious_Error := False;
1224          end if;
1225       end loop;
1226
1227       if Is_Warning_Msg or Is_Style_Msg then
1228          Is_Serious_Error := False;
1229       end if;
1230    end Test_Style_Warning_Serious_Msg;
1231
1232    --------------------------------
1233    -- Validate_Specific_Warnings --
1234    --------------------------------
1235
1236    procedure Validate_Specific_Warnings (Eproc : Error_Msg_Proc) is
1237    begin
1238       for J in Specific_Warnings.First .. Specific_Warnings.Last loop
1239          declare
1240             SWE : Specific_Warning_Entry renames Specific_Warnings.Table (J);
1241          begin
1242             if not SWE.Config then
1243                if SWE.Open then
1244                   Eproc.all
1245                     ("?pragma Warnings Off with no matching Warnings On",
1246                      SWE.Start);
1247                elsif not SWE.Used then
1248                   Eproc.all
1249                     ("?no warning suppressed by this pragma", SWE.Start);
1250                end if;
1251             end if;
1252          end;
1253       end loop;
1254    end Validate_Specific_Warnings;
1255
1256    -------------------------------------
1257    -- Warning_Specifically_Suppressed --
1258    -------------------------------------
1259
1260    function Warning_Specifically_Suppressed
1261      (Loc : Source_Ptr;
1262       Msg : String_Ptr) return Boolean
1263    is
1264       function Matches (S : String; P : String) return Boolean;
1265       --  Returns true if the String S patches the pattern P, which can contain
1266       --  wild card chars (*). The entire pattern must match the entire string.
1267
1268       -------------
1269       -- Matches --
1270       -------------
1271
1272       function Matches (S : String; P : String) return Boolean is
1273          Slast : constant Natural := S'Last;
1274          PLast : constant Natural := P'Last;
1275
1276          SPtr : Natural := S'First;
1277          PPtr : Natural := P'First;
1278
1279       begin
1280          --  Loop advancing through characters of string and pattern
1281
1282          SPtr := S'First;
1283          PPtr := P'First;
1284          loop
1285             --  Return True if pattern is a single asterisk
1286
1287             if PPtr = PLast and then P (PPtr) = '*' then
1288                return True;
1289
1290             --  Return True if both pattern and string exhausted
1291
1292             elsif PPtr > PLast and then SPtr > Slast then
1293                return True;
1294
1295             --  Return False, if one exhausted and not the other
1296
1297             elsif PPtr > PLast or else SPtr > Slast then
1298                return False;
1299
1300             --  Case where pattern starts with asterisk
1301
1302             elsif P (PPtr) = '*' then
1303
1304                --  Try all possible starting positions in S for match with
1305                --  the remaining characters of the pattern. This is the
1306                --  recursive call that implements the scanner backup.
1307
1308                for J in SPtr .. Slast loop
1309                   if Matches (S (J .. Slast), P (PPtr + 1 .. PLast)) then
1310                      return True;
1311                   end if;
1312                end loop;
1313
1314                return False;
1315
1316             --  Dealt with end of string and *, advance if we have a match
1317
1318             elsif S (SPtr) = P (PPtr) then
1319                SPtr := SPtr + 1;
1320                PPtr := PPtr + 1;
1321
1322             --  If first characters do not match, that's decisive
1323
1324             else
1325                return False;
1326             end if;
1327          end loop;
1328       end Matches;
1329
1330    --  Start of processing for Warning_Specifically_Suppressed
1331
1332    begin
1333       --  Loop through specific warning suppression entries
1334
1335       for J in Specific_Warnings.First .. Specific_Warnings.Last loop
1336          declare
1337             SWE : Specific_Warning_Entry renames Specific_Warnings.Table (J);
1338
1339          begin
1340             --  Pragma applies if it is a configuration pragma, or if the
1341             --  location is in range of a specific non-configuration pragma.
1342
1343             if SWE.Config
1344               or else (SWE.Start <= Loc and then Loc <= SWE.Stop)
1345             then
1346                if Matches (Msg.all, SWE.Msg.all) then
1347                   SWE.Used := True;
1348                   return True;
1349                end if;
1350             end if;
1351          end;
1352       end loop;
1353
1354       return False;
1355    end Warning_Specifically_Suppressed;
1356
1357    -------------------------
1358    -- Warnings_Suppressed --
1359    -------------------------
1360
1361    function Warnings_Suppressed (Loc : Source_Ptr) return Boolean is
1362    begin
1363       if Warning_Mode = Suppress then
1364          return True;
1365       end if;
1366
1367       --  Loop through table of ON/OFF warnings
1368
1369       for J in Warnings.First .. Warnings.Last loop
1370          if Warnings.Table (J).Start <= Loc
1371            and then Loc <= Warnings.Table (J).Stop
1372          then
1373             return True;
1374          end if;
1375       end loop;
1376
1377       return False;
1378    end Warnings_Suppressed;
1379
1380 end Erroutc;