OSDN Git Service

19cfa1841acd797e883862ea7458cd574cc14f12
[pf3gnuchains/gcc-fork.git] / gcc / ada / lib.ads
1 ------------------------------------------------------------------------------
2 --                                                                          --
3 --                         GNAT COMPILER COMPONENTS                         --
4 --                                                                          --
5 --                                  L I B                                   --
6 --                                                                          --
7 --                                 S p e c                                  --
8 --                                                                          --
9 --          Copyright (C) 1992-2007, Free Software Foundation, Inc.         --
10 --                                                                          --
11 -- GNAT is free software;  you can  redistribute it  and/or modify it under --
12 -- terms of the  GNU General Public License as published  by the Free Soft- --
13 -- ware  Foundation;  either version 2,  or (at your option) any later ver- --
14 -- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License --
17 -- for  more details.  You should have  received  a copy of the GNU General --
18 -- Public License  distributed with GNAT;  see file COPYING.  If not, write --
19 -- to  the  Free Software Foundation,  51  Franklin  Street,  Fifth  Floor, --
20 -- Boston, MA 02110-1301, USA.                                              --
21 --                                                                          --
22 -- As a special exception,  if other files  instantiate  generics from this --
23 -- unit, or you link  this unit with other files  to produce an executable, --
24 -- this  unit  does not  by itself cause  the resulting  executable  to  be --
25 -- covered  by the  GNU  General  Public  License.  This exception does not --
26 -- however invalidate  any other reasons why  the executable file  might be --
27 -- covered by the  GNU Public License.                                      --
28 --                                                                          --
29 -- GNAT was originally developed  by the GNAT team at  New York University. --
30 -- Extensive contributions were provided by Ada Core Technologies Inc.      --
31 --                                                                          --
32 ------------------------------------------------------------------------------
33
34 --  This package contains routines for accessing and outputting the library
35 --  information. It contains the routine to load subsidiary units.
36
37 with Alloc;
38 with Namet; use Namet;
39 with Table;
40 with Types; use Types;
41
42 package Lib is
43
44    --------------------------------------------
45    -- General Approach to Library Management --
46    --------------------------------------------
47
48    --  As described in GNote #1, when a unit is compiled, all its subsidiary
49    --  units are recompiled, including the following:
50
51    --    (a) Corresponding spec for a body
52    --    (b) Parent spec of a child library spec
53    --    (d) With'ed specs
54    --    (d) Parent body of a subunit
55    --    (e) Subunits corresponding to any specified stubs
56    --    (f) Bodies of inlined subprograms that are called
57    --    (g) Bodies of generic subprograms or packages that are instantiated
58    --    (h) Bodies of packages containing either of the above two items
59    --    (i) Specs and bodies of runtime units
60    --    (j) Parent specs for with'ed child library units
61
62    --  If a unit is being compiled only for syntax checking, then no subsidiary
63    --  units are loaded, the syntax check applies only to the main unit,
64    --  i.e. the one contained in the source submitted to the library.
65
66    --  If a unit is being compiled for syntax and semantic checking, then only
67    --  cases (a)-(d) loads are performed, since the full semantic checking can
68    --  be carried out without needing (e)-(i) loads. In this case no object
69    --  file, or library information file, is generated, so the missing units
70    --  do not affect the results.
71
72    --  Specifications of library subprograms, subunits, and generic specs
73    --  and bodies, can only be compiled in syntax/semantic checking mode,
74    --  since no code is ever generated directly for these units. In the case
75    --  of subunits, only the compilation of the ultimate parent unit generates
76    --  actual code. If a subunit is submitted to the compiler in syntax/
77    --  semantic checking mode, the parent (or parents in the nested case) are
78    --  semantically checked only up to the point of the corresponding stub.
79
80    --  If code is being generated, then all the above units are required,
81    --  although the need for bodies of inlined procedures can be suppressed
82    --  by the use of a switch that sets the mode to ignore pragma Inline
83    --  statements.
84
85    --  The two main sections of the front end, Par and Sem, are recursive.
86    --  Compilation proceeds unit by unit making recursive calls as necessary.
87    --  The process is controlled from the GNAT main program, which makes calls
88    --  to Par and Sem sequence for the main unit.
89
90    --  Par parses the given unit, and then, after the parse is complete, uses
91    --  the Par.Load subprogram to load all its subsidiary units in categories
92    --  (a)-(d) above, installing pointers to the loaded units in the parse
93    --  tree, as described in a later section of this spec. If any of these
94    --  required units is missing, a fatal error is signalled, so that no
95    --  attempt is made to run Sem in such cases, since it is assumed that
96    --  too many cascaded errors would result, and the confusion would not
97    --  be helpful.
98
99    --  Following the call to Par on the main unit, the entire tree of required
100    --  units is thus loaded, and Sem is called on the main unit. The parameter
101    --  passed to Sem is the unit to be analyzed. The visibility table, which
102    --  is a single global structure, starts out containing only the entries
103    --  for the visible entities in Standard. Every call to Sem establishes a
104    --  new scope stack table, pushing an entry for Standard on entry to provide
105    --  the proper initial scope environment.
106
107    --  Sem first proceeds to perform semantic analysis on the currently loaded
108    --  units as follows:
109
110    --    In the case of a body (case (a) above), Sem analyzes the corresponding
111    --    spec, using a recursive call to Sem. As is always expected to be the
112    --    case with calls to Sem, any entities installed in the visibility table
113    --    are removed on exit from Sem, so that these entities have to be
114    --    reinstalled on return to continue the analysis of the body which of
115    --    course needs visibility of these entities.
116    --
117    --    In the case of the parent of a child spec (case (b) above), a similar
118    --    call is made to Sem to analyze the parent. Again, on return, the
119    --    entities from the analyzed parent spec have to be installed in the
120    --    visibility table of the caller (the child unit), which must have
121    --    visibility to the entities in its parent spec.
122
123    --    For with'ed specs (case (c) above), a recursive call to Sem is made
124    --    to analyze each spec in turn. After all the spec's have been analyzed,
125    --    but not till that point, the entities from all the with'ed units are
126    --    reinstalled in the visibility table so that the caller can proceed
127    --    with the analysis of the unit doing the with's with the necessary
128    --    entities made either potentially use visible or visible by selection
129    --    as needed.
130
131    --    Case (d) arises when Sem is passed a subunit to analyze. This means
132    --    that the main unit is a subunit, and the unit passed to Sem is either
133    --    the main unit, or one of its ancestors that is still a subunit. Since
134    --    analysis must start at the top of the tree, Sem essentially cancels
135    --    the current call by immediately making a call to analyze the parent
136    --    (when this call is finished it immediately returns, so logically this
137    --    call is like a goto). The subunit will then be analyzed at the proper
138    --    time as described for the stub case. Note that we also turn off the
139    --    indication that code should be generated in this case, since the only
140    --    time we generate code for subunits is when compiling the main parent.
141
142    --    Case (e), subunits corresponding to stubs, are handled as the stubs
143    --    are encountered. There are three sub-cases:
144
145    --      If the subunit has already been loaded, then this means that the
146    --      main unit was a subunit, and we are back on our way down to it
147    --      after following the initial processing described for case (d).
148    --      In this case we analyze this particular subunit, as described
149    --      for the case where we are generating code, but when we get back
150    --      we are all done, since the rest of the parent is irrelevant. To
151    --      get out of the parent, we raise the exception Subunit_Found, which
152    --      is handled at the outer level of Sem.
153
154    --      The cases where the subunit has not already been loaded correspond
155    --      to cases where the main unit was a parent. In this case the action
156    --      depends on whether or not we are generating code. If we are not
157    --      generating code, then this is the case where we can simply ignore
158    --      the subunit, since in checking mode we don't even want to insist
159    --      that the subunit exist, much less waste time checking it.
160
161    --      If we are generating code, then we need to load and analyze
162    --      all subunits. This is achieved with a call to Lib.Load to load
163    --      and parse the unit, followed by processing that installs the
164    --      context clause of the subunit, analyzes the subunit, and then
165    --      removes the context clause (from the visibility chains of the
166    --      parent). Note that we do *not* do a recursive call to Sem in
167    --      this case, precisely because we need to do the analysis of the
168    --      subunit with the current visibility table and scope stack.
169
170    --    Case (f) applies only to subprograms for which a pragma Inline is
171    --    given, providing that the compiler is operating in the mode where
172    --    pragma Inline's are activated. When the expander encounters a call
173    --    to such a subprogram, it loads the body of the subprogram if it has
174    --    not already been loaded, and calls Sem to process it.
175
176    --    Case (g) is similar to case (f), except that the body of a generic
177    --    is unconditionally required, regardless of compiler mode settings.
178    --    As in the subprogram case, when the expander encounters a generic
179    --    instantiation, it loads the generic body of the subprogram if it
180    --    has not already been loaded, and calls Sem to process it.
181
182    --    Case (h) arises when a package contains either an inlined subprogram
183    --    which is called, or a generic which is instantiated. In this case the
184    --    body of the package must be loaded and analyzed with a call to Sem.
185
186    --    Case (i) is handled by adding implicit with clauses to the context
187    --    clauses of all units that potentially reference the relevant runtime
188    --    entities. Note that since we have the full set of units available,
189    --    the parser can always determine the set of runtime units that is
190    --    needed. These with clauses do not have associated use clauses, so
191    --    all references to the entities must be by selection. Once the with
192    --    clauses have been added, subsequent processing is as for normal
193    --    with clauses.
194
195    --    Case (j) is also handled by adding appropriate implicit with clauses
196    --    to any unit that withs a child unit. Again there is no use clause,
197    --    and subsequent processing proceeds as for an explicit with clause.
198
199    --  Sem thus completes the loading of all required units, except those
200    --  required for inline subprogram bodies or inlined generics. If any
201    --  of these load attempts fails, then the expander will not be called,
202    --  even if code was to be generated. If the load attempts all succeed
203    --  then the expander is called, though the attempt to generate code may
204    --  still fail if an error occurs during a load attempt for an inlined
205    --  body or a generic body.
206
207    -------------------------------------------
208    -- Special Handling of Subprogram Bodies --
209    -------------------------------------------
210
211    --  A subprogram body (in an adb file) may stand for both a spec and a
212    --  body. A simple model (and one that was adopted through version 2.07),
213    --  is simply to assume that such an adb file acts as its own spec if no
214    --  ads file is present.
215
216    --  However, this is not correct. RM 10.1.4(4) requires that such a body
217    --  act as a spec unless a subprogram declaration of the same name is
218    --  already present. The correct interpretation of this in GNAT library
219    --  terms is to ignore an existing ads file of the same name unless this
220    --  ads file contains a subprogram declaration with the same name.
221
222    --  If there is an ads file with a unit other than a subprogram declaration
223    --  with the same name, then a fatal message is output, noting that this
224    --  irrelevant file must be deleted before the body can be compiled. See
225    --  ACVC test CA1020D to see how this processing is required.
226
227    -----------------
228    -- Global Data --
229    -----------------
230
231    Current_Sem_Unit : Unit_Number_Type := Main_Unit;
232    --  Unit number of unit currently being analyzed/expanded. This is set when
233    --  ever a new unit is entered, saving and restoring the old value, so that
234    --  it always reflects the unit currently being analyzed. The initial value
235    --  of Main_Unit ensures that a proper value is set initially, and in
236    --  particular for analysis of configuration pragmas in gnat.adc.
237
238    Main_Unit_Entity : Entity_Id;
239    --  Entity of main unit, same as Cunit_Entity (Main_Unit) except where
240    --  Main_Unit is a body with a separate spec, in which case it is the
241    --  entity for the spec.
242
243    -----------------
244    -- Units Table --
245    -----------------
246
247    --  The units table has an entry for each unit (source file) read in by the
248    --  current compilation. The table is indexed by the unit number value,
249    --  The first entry in the table, subscript Main_Unit, is for the main file.
250    --  Each entry in this units table contains the following data.
251
252    --    Unit_File_Name
253    --      The name of the source file containing the unit. Set when the entry
254    --      is created by a call to Lib.Load, and then cannot be changed.
255
256    --    Source_Index
257    --      The index in the source file table of the corresponding source file.
258    --      Set when the entry is created by a call to Lib.Load and then cannot
259    --      be changed.
260
261    --    Munit_Index
262    --      The index of the unit within the file for multiple unit per file
263    --      mode. Set to zero in normal single unit per file mode.
264
265    --    Error_Location
266    --      This is copied from the Sloc field of the Enode argument passed
267    --      to Load_Unit. It refers to the enclosing construct which caused
268    --      this unit to be loaded, e.g. most typically the with clause that
269    --      referenced the unit, and is used for error handling in Par.Load.
270
271    --    Expected_Unit
272    --      This is the expected unit name for a file other than the main unit,
273    --      since these are cases where we load the unit using Lib.Load and we
274    --      know the unit that is expected. It must be the same as Unit_Name
275    --      if it is set (see test in Par.Load). Expected_Unit is set to
276    --      No_Name for the main unit.
277
278    --    Unit_Name
279    --      The name of the unit. Initialized to No_Name by Lib.Load, and then
280    --      set by the parser when the unit is parsed to the unit name actually
281    --      found in the file (which should, in the absence of errors) be the
282    --      same name as Expected_Unit.
283
284    --    Cunit
285    --      Pointer to the N_Compilation_Unit node. Initially set to Empty by
286    --      Lib.Load, and then reset to the required node by the parser when
287    --      the unit is parsed.
288
289    --    Cunit_Entity
290    --      Pointer to the entity node for the compilation unit. Initially set
291    --      to Empty by Lib.Load, and then reset to the required entity by the
292    --      parser when the unit is parsed.
293
294    --    Dependency_Num
295    --      This is the number of the unit within the generated dependency
296    --      lines (D lines in the ALI file) which are sorted into alphabetical
297    --      order. The number is ones origin, so a value of 2 refers to the
298    --      second generated D line. The Dependency_Number values are set
299    --      as the D lines are generated, and are used to generate proper
300    --      unit references in the generated xref information.
301
302    --    Dynamic_Elab
303    --      A flag indicating if this unit was compiled with dynamic elaboration
304    --      checks specified (as the result of using the -gnatE compilation
305    --      option or a pragma Elaboration_Checks (Dynamic).
306
307    --    Fatal_Error
308    --      A flag that is initialized to False, and gets set to True if a fatal
309    --      error occurs during the processing of a unit. A fatal error is one
310    --      defined as serious enough to stop the next phase of the compiler
311    --      from running (i.e. fatal error during parsing stops semantics,
312    --      fatal error during semantics stops code generation). Note that
313    --      currently, errors of any kind cause Fatal_Error to be set, but
314    --      eventually perhaps only errors labeled as Fatal_Errors should be
315    --      this severe if we decide to try Sem on sources with minor errors.
316
317    --    Generate_Code
318    --      This flag is set True for all units in the current file for which
319    --      code is to be generated. This includes the unit explicitly compiled,
320    --      together with its specification, and any subunits.
321
322    --    Has_RACW
323    --      A Boolean flag, initially set to False when a unit entry is created,
324    --      and set to True if the unit defines a remote access to class wide
325    --      (RACW) object. This is used for controlling generation of the RA
326    --      attribute in the ali file.
327
328    --    Is_Compiler_Unit
329    --      A Boolean flag, initially set False by default, set to True if a
330    --      pragma Compiler_Unit appears in the unit.
331
332    --    Ident_String
333    --      N_String_Literal node from a valid pragma Ident that applies to
334    --      this unit. If no Ident pragma applies to the unit, then Empty.
335
336    --    Loading
337    --      A flag that is used to catch circular WITH dependencies. It is set
338    --      True when an entry is initially created in the file table, and set
339    --      False when the load is completed, or ends with an error.
340
341    --    Main_Priority
342    --      This field is used to indicate the priority of a possible main
343    --      program, as set by a pragma Priority. A value of -1 indicates
344    --      that the default priority is to be used (and is also used for
345    --      entries that do not correspond to possible main programs).
346
347    --    Serial_Number
348    --      This field holds a serial number used by New_Internal_Name to
349    --      generate unique temporary numbers on a unit by unit basis. The
350    --      only access to this field is via the Increment_Serial_Number
351    --      routine which increments the current value and returns it. This
352    --      serial number is separate for each unit.
353
354    --    Version
355    --      This field holds the version of the unit, which is computed as
356    --      the exclusive or of the checksums of this unit, and all its
357    --      semantically dependent units. Access to the version number field
358    --      is not direct, but is done through the routines described below.
359    --      When a unit table entry is created, this field is initialized to
360    --      the checksum of the corresponding source file. Version_Update is
361    --      then called to reflect the contributions of any unit on which this
362    --      unit is semantically dependent.
363
364    --  The units table is reset to empty at the start of the compilation of
365    --  each main unit by Lib.Initialize. Entries are then added by calls to
366    --  the Lib.Load procedure. The following subprograms are used to access
367    --  and modify entries in the Units table. Individual entries are accessed
368    --  using a unit number value which ranges from Main_Unit (the first entry,
369    --  which is always for the current main unit) to Last_Unit.
370
371    Default_Main_Priority : constant Int := -1;
372    --  Value used in Main_Priority field to indicate default main priority
373
374    function Cunit            (U : Unit_Number_Type) return Node_Id;
375    function Cunit_Entity     (U : Unit_Number_Type) return Entity_Id;
376    function Dependency_Num   (U : Unit_Number_Type) return Nat;
377    function Dynamic_Elab     (U : Unit_Number_Type) return Boolean;
378    function Error_Location   (U : Unit_Number_Type) return Source_Ptr;
379    function Expected_Unit    (U : Unit_Number_Type) return Unit_Name_Type;
380    function Fatal_Error      (U : Unit_Number_Type) return Boolean;
381    function Generate_Code    (U : Unit_Number_Type) return Boolean;
382    function Ident_String     (U : Unit_Number_Type) return Node_Id;
383    function Has_RACW         (U : Unit_Number_Type) return Boolean;
384    function Is_Compiler_Unit (U : Unit_Number_Type) return Boolean;
385    function Loading          (U : Unit_Number_Type) return Boolean;
386    function Main_Priority    (U : Unit_Number_Type) return Int;
387    function Munit_Index      (U : Unit_Number_Type) return Nat;
388    function Source_Index     (U : Unit_Number_Type) return Source_File_Index;
389    function Unit_File_Name   (U : Unit_Number_Type) return File_Name_Type;
390    function Unit_Name        (U : Unit_Number_Type) return Unit_Name_Type;
391    --  Get value of named field from given units table entry
392
393    procedure Set_Cunit            (U : Unit_Number_Type; N : Node_Id);
394    procedure Set_Cunit_Entity     (U : Unit_Number_Type; E : Entity_Id);
395    procedure Set_Dynamic_Elab     (U : Unit_Number_Type; B : Boolean := True);
396    procedure Set_Error_Location   (U : Unit_Number_Type; W : Source_Ptr);
397    procedure Set_Fatal_Error      (U : Unit_Number_Type; B : Boolean := True);
398    procedure Set_Generate_Code    (U : Unit_Number_Type; B : Boolean := True);
399    procedure Set_Has_RACW         (U : Unit_Number_Type; B : Boolean := True);
400    procedure Set_Is_Compiler_Unit (U : Unit_Number_Type; B : Boolean := True);
401    procedure Set_Ident_String     (U : Unit_Number_Type; N : Node_Id);
402    procedure Set_Loading          (U : Unit_Number_Type; B : Boolean := True);
403    procedure Set_Main_Priority    (U : Unit_Number_Type; P : Int);
404    procedure Set_Unit_Name        (U : Unit_Number_Type; N : Unit_Name_Type);
405    --  Set value of named field for given units table entry. Note that we
406    --  do not have an entry for each possible field, since some of the fields
407    --  can only be set by specialized interfaces (defined below).
408
409    function Version_Get (U : Unit_Number_Type) return Word_Hex_String;
410    --  Returns the version as a string with 8 hex digits (upper case letters)
411
412    function Last_Unit return Unit_Number_Type;
413    --  Unit number of last allocated unit
414
415    function Num_Units return Nat;
416    --  Number of units currently in unit table
417
418    procedure Remove_Unit (U : Unit_Number_Type);
419    --  Remove unit U from unit table. Currently this is effective only
420    --  if U is the last unit currently stored in the unit table.
421
422    function Entity_Is_In_Main_Unit (E : Entity_Id) return Boolean;
423    --  Returns True if the entity E is declared in the main unit, or, in
424    --  its corresponding spec, or one of its subunits. Entities declared
425    --  within generic instantiations return True if the instantiation is
426    --  itself "in the main unit" by this definition. Otherwise False.
427
428    function Get_Source_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type;
429    pragma Inline (Get_Source_Unit);
430    function Get_Source_Unit (S : Source_Ptr) return Unit_Number_Type;
431    --  Return unit number of file identified by given source pointer value.
432    --  This call must always succeed, since any valid source pointer value
433    --  belongs to some previously loaded module. If the given source pointer
434    --  value is within an instantiation, this function returns the unit number
435    --  of the template, i.e. the unit containing the source code corresponding
436    --  to the given Source_Ptr value. The version taking a Node_Id argument, N,
437    --  simply applies the function to Sloc (N).
438
439    function Get_Code_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type;
440    pragma Inline (Get_Code_Unit);
441    function Get_Code_Unit (S : Source_Ptr) return Unit_Number_Type;
442    --  This is like Get_Source_Unit, except that in the instantiation case,
443    --  it uses the location of the top level instantiation, rather than the
444    --  template, so it returns the unit number containing the code that
445    --  corresponds to the node N, or the source location S.
446
447    function In_Same_Source_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
448    pragma Inline (In_Same_Source_Unit);
449    --  Determines if the two nodes or entities N1 and N2 are in the same
450    --  source unit, the criterion being that Get_Source_Unit yields the
451    --  same value for each argument.
452
453    function In_Same_Code_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
454    pragma Inline (In_Same_Code_Unit);
455    --  Determines if the two nodes or entities N1 and N2 are in the same
456    --  code unit, the criterion being that Get_Code_Unit yields the same
457    --  value for each argument.
458
459    function In_Same_Extended_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
460    pragma Inline (In_Same_Extended_Unit);
461    --  Determines if two nodes or entities N1 and N2 are in the same
462    --  extended unit, where an extended unit is defined as a unit and all
463    --  its subunits (considered recursively, i.e. subunits of subunits are
464    --  included). Returns true if S1 and S2 are in the same extended unit
465    --  and False otherwise.
466
467    function In_Same_Extended_Unit (S1, S2 : Source_Ptr) return Boolean;
468    pragma Inline (In_Same_Extended_Unit);
469    --  Determines if the two source locations S1 and S2 are in the same
470    --  extended unit, where an extended unit is defined as a unit and all
471    --  its subunits (considered recursively, i.e. subunits of subunits are
472    --  included). Returns true if S1 and S2 are in the same extended unit
473    --  and False otherwise.
474
475    function In_Extended_Main_Code_Unit
476      (N : Node_Or_Entity_Id) return Boolean;
477    --  Return True if the node is in the generated code of the extended main
478    --  unit, defined as the main unit, its specification (if any), and all
479    --  its subunits (considered recursively). Units for which this enquiry
480    --  returns True are those for which code will be generated. Nodes from
481    --  instantiations are included in the extended main unit for this call.
482    --  If the main unit is itself a subunit, then the extended main unit
483    --  includes its parent unit, and the parent unit spec if it is separate.
484
485    function In_Extended_Main_Code_Unit (Loc : Source_Ptr) return Boolean;
486    --  Same function as above, but argument is a source pointer rather
487    --  than a node.
488
489    function In_Extended_Main_Source_Unit
490      (N : Node_Or_Entity_Id) return Boolean;
491    --  Return True if the node is in the source text of the extended main
492    --  unit, defined as the main unit, its specification (if any), and all
493    --  its subunits (considered recursively). Units for which this enquiry
494    --  returns True are those for which code will be generated. This differs
495    --  from In_Extended_Main_Code_Unit only in that instantiations are not
496    --  included for the purposes of this call. If the main unit is itself
497    --  a subunit, then the extended main unit includes its parent unit,
498    --  and the parent unit spec if it is separate.
499
500    function In_Extended_Main_Source_Unit (Loc : Source_Ptr) return Boolean;
501    --  Same function as above, but argument is a source pointer
502
503    function In_Predefined_Unit (N : Node_Or_Entity_Id) return Boolean;
504    --  Returns True if the given node or entity appears within the source text
505    --  of a predefined unit (i.e. within Ada, Interfaces, System or within one
506    --  of the descendent packages of one of these three packages).
507
508    function In_Predefined_Unit (S : Source_Ptr) return Boolean;
509    --  Same function as above but argument is a source pointer
510
511    function Earlier_In_Extended_Unit (S1, S2 : Source_Ptr) return Boolean;
512    --  Given two Sloc values  for which In_Same_Extended_Unit is true,
513    --  determine if S1 appears before S2. Returns True if S1 appears before
514    --  S2, and False otherwise. The result is undefined if S1 and S2 are
515    --  not in the same extended unit.
516
517    function Compilation_Switches_Last return Nat;
518    --  Return the count of stored compilation switches
519
520    function Get_Compilation_Switch (N : Pos) return String_Ptr;
521    --  Return the Nth stored compilation switch, or null if less than N
522    --  switches have been stored. Used by ASIS and back ends written in Ada.
523
524    function Get_Cunit_Unit_Number (N : Node_Id) return Unit_Number_Type;
525    --  Return unit number of the unit whose N_Compilation_Unit node is the
526    --  one passed as an argument. This must always succeed since the node
527    --  could not have been built without making a unit table entry.
528
529    function Get_Cunit_Entity_Unit_Number
530      (E : Entity_Id) return Unit_Number_Type;
531    --  Return unit number of the unit whose compilation unit spec entity is
532    --  the one passed as an argument. This must always succeed since the
533    --  entity could not have been built without making a unit table entry.
534
535    function Increment_Serial_Number return Nat;
536    --  Increment Serial_Number field for current unit, and return the
537    --  incremented value.
538
539    procedure Synchronize_Serial_Number;
540    --  This function increments the Serial_Number field for the current unit
541    --  but does not return the incremented value. This is used when there
542    --  is a situation where one path of control increments a serial number
543    --  (using Increment_Serial_Number), and the other path does not and it is
544    --  important to keep the serial numbers synchronized in the two cases (e.g.
545    --  when the references in a package and a client must be kept consistent).
546
547    procedure Replace_Linker_Option_String
548      (S            : String_Id;
549       Match_String : String);
550    --  Replace an existing Linker_Option if the prefix Match_String matches,
551    --  otherwise call Store_Linker_Option_String.
552
553    procedure Store_Compilation_Switch (Switch : String);
554    --  Called to register a compilation switch, either front-end or back-end,
555    --  which may influence the generated output file(s). Switch is the text of
556    --  the switch to store (except that -fRTS gets changed back to --RTS).
557
558    procedure Disable_Switch_Storing;
559    --  Disable registration of switches by Store_Compilation_Switch. Used to
560    --  avoid registering switches added automatically by the gcc driver.
561
562    procedure Store_Linker_Option_String (S : String_Id);
563    --  This procedure is called to register the string from a pragma
564    --  Linker_Option. The argument is the Id of the string to register.
565
566    procedure Initialize;
567    --  Initialize internal tables
568
569    procedure Lock;
570    --  Lock internal tables before calling back end
571
572    procedure Unlock;
573    --  Unlock internal tables, in cases where the back end needs to modify them
574
575    procedure Tree_Read;
576    --  Initializes internal tables from current tree file using the relevant
577    --  Table.Tree_Read routines.
578
579    procedure Tree_Write;
580    --  Writes out internal tables to current tree file using the relevant
581    --  Table.Tree_Write routines.
582
583    function Is_Loaded (Uname : Unit_Name_Type) return Boolean;
584    --  Determines if unit with given name is already loaded, i.e. there is
585    --  already an entry in the file table with this unit name for which the
586    --  corresponding file was found and parsed. Note that the Fatal_Error flag
587    --  of this entry must be checked before proceeding with further processing.
588
589    procedure Version_Referenced (S : String_Id);
590    --  This routine is called from Exp_Attr to register the use of a Version
591    --  or Body_Version attribute. The argument is the external name used to
592    --  access the version string.
593
594    procedure List (File_Names_Only : Boolean := False);
595    --  Lists units in active library (i.e. generates output consisting of a
596    --  sorted listing of the units represented in File table, except for the
597    --  main unit). If File_Names_Only is set to True, then the list includes
598    --  only file names, and no other information. Otherwise the unit name and
599    --  time stamp are also output. File_Names_Only also restricts the list to
600    --  exclude any predefined files.
601
602    function Generic_May_Lack_ALI (Sfile : File_Name_Type) return Boolean;
603    --  Generic units must be separately compiled. Since we always use
604    --  macro substitution for generics, the resulting object file is a dummy
605    --  one with no code, but the ALI file has the normal form, and we need
606    --  this ALI file so that the binder can work out a correct order of
607    --  elaboration.
608
609    --  However, ancient versions of GNAT used to not generate code or ALI
610    --  files for generic units, and this would yield complex order of
611    --  elaboration issues. These were fixed in GNAT 3.10. The support for not
612    --  compiling language-defined library generics was retained nonetheless
613    --  to facilitate bootstrap. Specifically, it is convenient to have
614    --  the same list of files to be compiled for all stages. So, if the
615    --  bootstrap compiler does not generate code for a given file, then
616    --  the stage1 compiler (and binder) also must deal with the case of
617    --  that file not being compiled. The predicate Generic_May_Lack_ALI is
618    --  True for those generic units for which missing ALI files are allowed.
619
620 private
621    pragma Inline (Cunit);
622    pragma Inline (Cunit_Entity);
623    pragma Inline (Dependency_Num);
624    pragma Inline (Fatal_Error);
625    pragma Inline (Generate_Code);
626    pragma Inline (Has_RACW);
627    pragma Inline (Is_Compiler_Unit);
628    pragma Inline (Increment_Serial_Number);
629    pragma Inline (Loading);
630    pragma Inline (Main_Priority);
631    pragma Inline (Munit_Index);
632    pragma Inline (Set_Cunit);
633    pragma Inline (Set_Cunit_Entity);
634    pragma Inline (Set_Fatal_Error);
635    pragma Inline (Set_Generate_Code);
636    pragma Inline (Set_Has_RACW);
637    pragma Inline (Set_Loading);
638    pragma Inline (Set_Main_Priority);
639    pragma Inline (Set_Unit_Name);
640    pragma Inline (Source_Index);
641    pragma Inline (Unit_File_Name);
642    pragma Inline (Unit_Name);
643
644    type Unit_Record is record
645       Unit_File_Name   : File_Name_Type;
646       Unit_Name        : Unit_Name_Type;
647       Munit_Index      : Nat;
648       Expected_Unit    : Unit_Name_Type;
649       Source_Index     : Source_File_Index;
650       Cunit            : Node_Id;
651       Cunit_Entity     : Entity_Id;
652       Dependency_Num   : Int;
653       Ident_String     : Node_Id;
654       Main_Priority    : Int;
655       Serial_Number    : Nat;
656       Version          : Word;
657       Error_Location   : Source_Ptr;
658       Fatal_Error      : Boolean;
659       Generate_Code    : Boolean;
660       Has_RACW         : Boolean;
661       Is_Compiler_Unit : Boolean;
662       Dynamic_Elab     : Boolean;
663       Loading          : Boolean;
664    end record;
665
666    --  The following representation clause ensures that the above record
667    --  has no holes. We do this so that when instances of this record are
668    --  written by Tree_Gen, we do not write uninitialized values to the file.
669
670    for Unit_Record use record
671       Unit_File_Name   at  0 range 0 .. 31;
672       Unit_Name        at  4 range 0 .. 31;
673       Munit_Index      at  8 range 0 .. 31;
674       Expected_Unit    at 12 range 0 .. 31;
675       Source_Index     at 16 range 0 .. 31;
676       Cunit            at 20 range 0 .. 31;
677       Cunit_Entity     at 24 range 0 .. 31;
678       Dependency_Num   at 28 range 0 .. 31;
679       Ident_String     at 32 range 0 .. 31;
680       Main_Priority    at 36 range 0 .. 31;
681       Serial_Number    at 40 range 0 .. 31;
682       Version          at 44 range 0 .. 31;
683       Error_Location   at 48 range 0 .. 31;
684       Fatal_Error      at 52 range 0 ..  7;
685       Generate_Code    at 53 range 0 ..  7;
686       Has_RACW         at 54 range 0 ..  7;
687       Dynamic_Elab     at 55 range 0 ..  7;
688       Is_Compiler_Unit at 56 range 0 .. 31;
689       Loading          at 60 range 0 .. 31;
690    end record;
691
692    for Unit_Record'Size use 64 * 8;
693    --  This ensures that we did not leave out any fields
694
695    package Units is new Table.Table (
696      Table_Component_Type => Unit_Record,
697      Table_Index_Type     => Unit_Number_Type,
698      Table_Low_Bound      => Main_Unit,
699      Table_Initial        => Alloc.Units_Initial,
700      Table_Increment      => Alloc.Units_Increment,
701      Table_Name           => "Units");
702
703    --  The following table stores strings from pragma Linker_Option lines
704
705    type Linker_Option_Entry is record
706       Option : String_Id;
707       --  The string for the linker option line
708
709       Unit : Unit_Number_Type;
710       --  The unit from which the linker option comes
711    end record;
712
713    package Linker_Option_Lines is new Table.Table (
714      Table_Component_Type => Linker_Option_Entry,
715      Table_Index_Type     => Integer,
716      Table_Low_Bound      => 1,
717      Table_Initial        => Alloc.Linker_Option_Lines_Initial,
718      Table_Increment      => Alloc.Linker_Option_Lines_Increment,
719      Table_Name           => "Linker_Option_Lines");
720
721    --  The following table records the compilation switches used to compile
722    --  the main unit. The table includes only switches and excludes -quiet,
723    --  -dumpbase, and -o switches, since the latter are typically artifacts
724    --  of the gcc/gnat1 interface.
725
726    --  This table is set as part of the compiler argument scanning in
727    --  Back_End. It can also be reset in -gnatc mode from the data in an
728    --  existing ali file, and is read and written by the Tree_Read and
729    --  Tree_Write routines for ASIS.
730
731    package Compilation_Switches is new Table.Table (
732      Table_Component_Type => String_Ptr,
733      Table_Index_Type     => Nat,
734      Table_Low_Bound      => 1,
735      Table_Initial        => 30,
736      Table_Increment      => 100,
737      Table_Name           => "Compilation_Switches");
738
739    Load_Msg_Sloc : Source_Ptr;
740    --  Location for placing error messages (a token in the main source text)
741    --  This is set from Sloc (Enode) by Load only in the case where this Sloc
742    --  is in the main source file. This ensures that not found messages and
743    --  circular dependency messages reference the original with in this source.
744
745    type Unit_Ref_Table is array (Pos range <>) of Unit_Number_Type;
746    --  Type to hold list of indirect references to unit number table
747
748    type Load_Stack_Entry is record
749       Unit_Number : Unit_Number_Type;
750       With_Node   : Node_Id;
751    end record;
752
753    --  The Load_Stack table contains a list of unit numbers (indices into the
754    --  unit table) of units being loaded on a single dependency chain, and a
755    --  flag to indicate whether this unit is loaded through a limited_with
756    --  clause. The First entry is the main unit. The second entry, if present
757    --  is a unit on which the first unit depends, etc. This stack is used to
758    --  generate error messages showing the dependency chain if a file is not
759    --  found, or whether a true circular dependency exists.  The Load_Unit
760    --  function makes an entry in this table when it is called, and removes
761    --  the entry just before it returns.
762
763    package Load_Stack is new Table.Table (
764      Table_Component_Type => Load_Stack_Entry,
765      Table_Index_Type     => Int,
766      Table_Low_Bound      => 0,
767      Table_Initial        => Alloc.Load_Stack_Initial,
768      Table_Increment      => Alloc.Load_Stack_Increment,
769      Table_Name           => "Load_Stack");
770
771    procedure Sort (Tbl : in out Unit_Ref_Table);
772    --  This procedure sorts the given unit reference table in order of
773    --  ascending unit names, where the ordering relation is as described
774    --  by the comparison routines provided by package Uname.
775
776    --  The Version_Ref table records Body_Version and Version attribute
777    --  references. The entries are simply the strings for the external
778    --  names that correspond to the referenced values.
779
780    package Version_Ref is new Table.Table (
781      Table_Component_Type => String_Id,
782      Table_Index_Type     => Nat,
783      Table_Low_Bound      => 1,
784      Table_Initial        => 20,
785      Table_Increment      => 100,
786      Table_Name           => "Version_Ref");
787
788 end Lib;