OSDN Git Service

PR middle-end/42068
[pf3gnuchains/gcc-fork.git] / gcc / ada / par-ch10.adb
1 ------------------------------------------------------------------------------
2 --                                                                          --
3 --                         GNAT COMPILER COMPONENTS                         --
4 --                                                                          --
5 --                             P A R . C H 1 0                              --
6 --                                                                          --
7 --                                 B o d y                                  --
8 --                                                                          --
9 --          Copyright (C) 1992-2009, Free Software Foundation, Inc.         --
10 --                                                                          --
11 -- GNAT is free software;  you can  redistribute it  and/or modify it under --
12 -- terms of the  GNU General Public License as published  by the Free Soft- --
13 -- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14 -- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License --
17 -- for  more details.  You should have  received  a copy of the GNU General --
18 -- Public License  distributed with GNAT; see file COPYING3.  If not, go to --
19 -- http://www.gnu.org/licenses for a complete copy of the license.          --
20 --                                                                          --
21 -- GNAT was originally developed  by the GNAT team at  New York University. --
22 -- Extensive contributions were provided by Ada Core Technologies Inc.      --
23 --                                                                          --
24 ------------------------------------------------------------------------------
25
26 pragma Style_Checks (All_Checks);
27 --  Turn off subprogram body ordering check. Subprograms are in order
28 --  by RM section rather than alphabetical
29
30 with Fname.UF; use Fname.UF;
31 with Uname;    use Uname;
32
33 separate (Par)
34 package body Ch10 is
35
36    --  Local functions, used only in this chapter
37
38    function P_Context_Clause    return List_Id;
39    function P_Subunit           return Node_Id;
40
41    function Set_Location return Source_Ptr;
42    --  The current compilation unit starts with Token at Token_Ptr. This
43    --  function determines the corresponding source location for the start
44    --  of the unit, including any preceding comment lines.
45
46    procedure Unit_Display
47      (Cunit      : Node_Id;
48       Loc        : Source_Ptr;
49       SR_Present : Boolean);
50    --  This procedure is used to generate a line of output for a unit in
51    --  the source program. Cunit is the node for the compilation unit, and
52    --  Loc is the source location for the start of the unit in the source
53    --  file (which is not necessarily the Sloc of the Cunit node). This
54    --  output is written to the standard output file for use by gnatchop.
55
56    procedure Unit_Location (Sind : Source_File_Index; Loc : Source_Ptr);
57    --  This routine has the same calling sequence as Unit_Display, but
58    --  it outputs only the line number and offset of the location, Loc,
59    --  using Cunit to obtain the proper source file index.
60
61    -------------------------
62    -- 10.1.1  Compilation --
63    -------------------------
64
65    --  COMPILATION ::= {COMPILATION_UNIT}
66
67    --  There is no specific parsing routine for a compilation, since we only
68    --  permit a single compilation in a source file, so there is no explicit
69    --  occurrence of compilations as such (our representation of a compilation
70    --  is a series of separate source files).
71
72    ------------------------------
73    -- 10.1.1  Compilation unit --
74    ------------------------------
75
76    --  COMPILATION_UNIT ::=
77    --    CONTEXT_CLAUSE LIBRARY_ITEM
78    --  | CONTEXT_CLAUSE SUBUNIT
79
80    --  LIBRARY_ITEM ::=
81    --    private LIBRARY_UNIT_DECLARATION
82    --  | LIBRARY_UNIT_BODY
83    --  | [private] LIBRARY_UNIT_RENAMING_DECLARATION
84
85    --  LIBRARY_UNIT_DECLARATION ::=
86    --    SUBPROGRAM_DECLARATION | PACKAGE_DECLARATION
87    --  | GENERIC_DECLARATION    | GENERIC_INSTANTIATION
88
89    --  LIBRARY_UNIT_RENAMING_DECLARATION ::=
90    --    PACKAGE_RENAMING_DECLARATION
91    --  | GENERIC_RENAMING_DECLARATION
92    --  | SUBPROGRAM_RENAMING_DECLARATION
93
94    --  LIBRARY_UNIT_BODY ::= SUBPROGRAM_BODY | PACKAGE_BODY
95
96    --  Error recovery: cannot raise Error_Resync. If an error occurs, tokens
97    --  are skipped up to the next possible beginning of a compilation unit.
98
99    --  Note: if only configuration pragmas are found, Empty is returned
100
101    --  Note: in syntax-only mode, it is possible for P_Compilation_Unit
102    --  to return strange things that are not really compilation units.
103    --  This is done to help out gnatchop when it is faced with nonsense.
104
105    function P_Compilation_Unit return Node_Id is
106       Scan_State         : Saved_Scan_State;
107       Body_Node          : Node_Id;
108       Specification_Node : Node_Id;
109       Unit_Node          : Node_Id;
110       Comp_Unit_Node     : Node_Id;
111       Name_Node          : Node_Id;
112       Item               : Node_Id;
113       Private_Sloc       : Source_Ptr := No_Location;
114       Config_Pragmas     : List_Id;
115       P                  : Node_Id;
116       SR_Present         : Boolean;
117
118       Cunit_Error_Flag : Boolean := False;
119       --  This flag is set True if we have to scan for a compilation unit
120       --  token. It is used to ensure clean termination in such cases by
121       --  not insisting on being at the end of file, and, in the syntax only
122       --  case by not scanning for additional compilation units.
123
124       Cunit_Location : Source_Ptr;
125       --  Location of unit for unit identification output (List_Unit option)
126
127    begin
128       Num_Library_Units := Num_Library_Units + 1;
129
130       --  Set location of the compilation unit if unit list option set
131       --  and we are in syntax check only mode
132
133       if List_Units and then Operating_Mode = Check_Syntax then
134          Cunit_Location := Set_Location;
135       else
136          Cunit_Location := No_Location;
137       end if;
138
139       --  Deal with initial pragmas
140
141       Config_Pragmas := No_List;
142
143       --  If we have an initial Source_Reference pragma, then remember the fact
144       --  to generate an NR parameter in the output line.
145
146       SR_Present := False;
147
148       if Token = Tok_Pragma then
149          Save_Scan_State (Scan_State);
150          Item := P_Pragma;
151
152          if Item = Error
153            or else Pragma_Name (Item) /= Name_Source_Reference
154          then
155             Restore_Scan_State (Scan_State);
156
157          else
158             SR_Present := True;
159
160             --  If first unit, record the file name for gnatchop use
161
162             if Operating_Mode = Check_Syntax
163               and then List_Units
164               and then Num_Library_Units = 1
165             then
166                Write_Str ("Source_Reference pragma for file """);
167                Write_Name (Full_Ref_Name (Current_Source_File));
168                Write_Char ('"');
169                Write_Eol;
170             end if;
171
172             Config_Pragmas := New_List (Item);
173          end if;
174       end if;
175
176       --  Scan out any configuration pragmas
177
178       while Token = Tok_Pragma loop
179          Save_Scan_State (Scan_State);
180          Item := P_Pragma;
181
182          if Item = Error
183            or else not Is_Configuration_Pragma_Name (Pragma_Name (Item))
184          then
185             Restore_Scan_State (Scan_State);
186             exit;
187          end if;
188
189          if Config_Pragmas = No_List then
190             Config_Pragmas := Empty_List;
191
192             if Operating_Mode = Check_Syntax and then List_Units then
193                Write_Str ("Configuration pragmas at");
194                Unit_Location (Current_Source_File, Cunit_Location);
195                Write_Eol;
196             end if;
197          end if;
198
199          Append (Item, Config_Pragmas);
200          Cunit_Location := Set_Location;
201       end loop;
202
203       --  Establish compilation unit node and scan context items
204
205       Comp_Unit_Node := New_Node (N_Compilation_Unit, No_Location);
206       Set_Cunit (Current_Source_Unit, Comp_Unit_Node);
207       Set_Context_Items (Comp_Unit_Node, P_Context_Clause);
208       Set_Aux_Decls_Node
209         (Comp_Unit_Node, New_Node (N_Compilation_Unit_Aux, No_Location));
210
211       if Present (Config_Pragmas) then
212
213          --  Check for case of only configuration pragmas present
214
215          if Token = Tok_EOF
216            and then Is_Empty_List (Context_Items (Comp_Unit_Node))
217          then
218             if Operating_Mode = Check_Syntax then
219                return Empty;
220
221             else
222                Item := First (Config_Pragmas);
223                Error_Msg_N
224                  ("cannot compile configuration pragmas with gcc!", Item);
225                Error_Msg_N
226                  ("\use gnatchop -c to process configuration pragmas!", Item);
227                raise Unrecoverable_Error;
228             end if;
229
230          --  Otherwise configuration pragmas are simply prepended to the
231          --  context of the current unit.
232
233          else
234             Append_List (Context_Items (Comp_Unit_Node), Config_Pragmas);
235             Set_Context_Items (Comp_Unit_Node, Config_Pragmas);
236          end if;
237       end if;
238
239       --  Check for PRIVATE. Note that for the moment we allow this in
240       --  Ada_83 mode, since we do not yet know if we are compiling a
241       --  predefined unit, and if we are then it would be allowed anyway.
242
243       if Token = Tok_Private then
244          Private_Sloc := Token_Ptr;
245          Set_Keyword_Casing (Current_Source_File, Determine_Token_Casing);
246
247          if Style_Check then
248             Style.Check_Indentation;
249          end if;
250
251          Save_Scan_State (Scan_State); -- at PRIVATE
252          Scan; -- past PRIVATE
253
254          if Token = Tok_Separate then
255             Error_Msg_SP ("cannot have private subunits!");
256
257          elsif Token = Tok_Package then
258             Scan; -- past PACKAGE
259
260             if Token = Tok_Body then
261                Restore_Scan_State (Scan_State); -- to PRIVATE
262                Error_Msg_SC ("cannot have private package body!");
263                Scan; -- ignore PRIVATE
264
265             else
266                Restore_Scan_State (Scan_State); -- to PRIVATE
267                Scan; -- past PRIVATE
268                Set_Private_Present (Comp_Unit_Node, True);
269             end if;
270
271          elsif Token = Tok_Procedure
272            or else Token = Tok_Function
273            or else Token = Tok_Generic
274          then
275             Set_Private_Present (Comp_Unit_Node, True);
276          end if;
277       end if;
278
279       --  Loop to find our way to a compilation unit token
280
281       loop
282          exit when Token in Token_Class_Cunit and then Token /= Tok_With;
283
284          exit when Bad_Spelling_Of (Tok_Package)
285            or else Bad_Spelling_Of (Tok_Function)
286            or else Bad_Spelling_Of (Tok_Generic)
287            or else Bad_Spelling_Of (Tok_Separate)
288            or else Bad_Spelling_Of (Tok_Procedure);
289
290          --  Allow task and protected for nice error recovery purposes
291
292          exit when Token = Tok_Task
293            or else Token = Tok_Protected;
294
295          if Token = Tok_With then
296             Error_Msg_SC ("misplaced WITH");
297             Append_List (P_Context_Clause, Context_Items (Comp_Unit_Node));
298
299          elsif Bad_Spelling_Of (Tok_With) then
300             Append_List (P_Context_Clause, Context_Items (Comp_Unit_Node));
301
302          else
303             if Operating_Mode = Check_Syntax and then Token = Tok_EOF then
304                Error_Msg_SC ("?file contains no compilation units");
305             else
306                Error_Msg_SC ("compilation unit expected");
307                Cunit_Error_Flag := True;
308                Resync_Cunit;
309             end if;
310
311             --  If we are at an end of file, then just quit, the above error
312             --  message was complaint enough.
313
314             if Token = Tok_EOF then
315                return Error;
316             end if;
317          end if;
318       end loop;
319
320       --  We have a compilation unit token, so that's a reasonable choice for
321       --  determining the standard casing convention used for keywords in case
322       --  it hasn't already been done on seeing a WITH or PRIVATE.
323
324       Set_Keyword_Casing (Current_Source_File, Determine_Token_Casing);
325
326       if Style_Check then
327          Style.Check_Indentation;
328       end if;
329
330       --  Remaining processing depends on particular type of compilation unit
331
332       if Token = Tok_Package then
333
334          --  A common error is to omit the body keyword after package. We can
335          --  often diagnose this early on (before getting loads of errors from
336          --  contained subprogram bodies), by knowing that the file we
337          --  are compiling has a name that requires a body to be found.
338
339          Save_Scan_State (Scan_State);
340          Scan; -- past Package keyword
341
342          if Token /= Tok_Body
343            and then
344              Get_Expected_Unit_Type
345                (File_Name (Current_Source_File)) = Expect_Body
346          then
347             Error_Msg_BC ("keyword BODY expected here [see file name]");
348             Restore_Scan_State (Scan_State);
349             Set_Unit (Comp_Unit_Node, P_Package (Pf_Pbod));
350          else
351             Restore_Scan_State (Scan_State);
352             Set_Unit (Comp_Unit_Node, P_Package (Pf_Decl_Gins_Pbod_Rnam));
353          end if;
354
355       elsif Token = Tok_Generic then
356          Set_Unit (Comp_Unit_Node, P_Generic);
357
358       elsif Token = Tok_Separate then
359          Set_Unit (Comp_Unit_Node, P_Subunit);
360
361       elsif Token = Tok_Function
362         or else Token = Tok_Not
363         or else Token = Tok_Overriding
364         or else Token = Tok_Procedure
365       then
366          Set_Unit (Comp_Unit_Node, P_Subprogram (Pf_Decl_Gins_Pbod_Rnam));
367
368          --  A little bit of an error recovery check here. If we just scanned
369          --  a subprogram declaration (as indicated by an SIS entry being
370          --  active), then if the following token is BEGIN or an identifier,
371          --  or a token which can reasonably start a declaration but cannot
372          --  start a compilation unit, then we assume that the semicolon in
373          --  the declaration should have been IS.
374
375          if SIS_Entry_Active then
376
377             if Token = Tok_Begin
378                or else Token = Tok_Identifier
379                or else Token in Token_Class_Deckn
380             then
381                Push_Scope_Stack;
382                Scope.Table (Scope.Last).Etyp := E_Name;
383                Scope.Table (Scope.Last).Sloc := SIS_Sloc;
384                Scope.Table (Scope.Last).Ecol := SIS_Ecol;
385                Scope.Table (Scope.Last).Lreq := False;
386                SIS_Entry_Active := False;
387
388                --  If we had a missing semicolon in the declaration, then
389                --  change the message to from <missing ";"> to <missing "is">
390
391                if SIS_Missing_Semicolon_Message /= No_Error_Msg then
392                   Change_Error_Text     -- Replace: "missing "";"" "
393                     (SIS_Missing_Semicolon_Message, "missing IS");
394
395                --  Otherwise we saved the semicolon position, so complain
396
397                else
398                   Error_Msg (""";"" should be IS", SIS_Semicolon_Sloc);
399                end if;
400
401                Body_Node := Unit (Comp_Unit_Node);
402                Specification_Node := Specification (Body_Node);
403                Change_Node (Body_Node, N_Subprogram_Body);
404                Set_Specification (Body_Node, Specification_Node);
405                Parse_Decls_Begin_End (Body_Node);
406                Set_Unit (Comp_Unit_Node, Body_Node);
407             end if;
408
409          --  If we scanned a subprogram body, make sure we did not have private
410
411          elsif Private_Sloc /= No_Location
412            and then
413              Nkind (Unit (Comp_Unit_Node)) not in N_Subprogram_Instantiation
414            and then
415              Nkind (Unit (Comp_Unit_Node)) /= N_Subprogram_Renaming_Declaration
416          then
417             Error_Msg ("cannot have private subprogram body", Private_Sloc);
418
419          --  P_Subprogram can yield an abstract subprogram, but this cannot
420          --  be a compilation unit. Treat as a subprogram declaration.
421
422          elsif
423            Nkind (Unit (Comp_Unit_Node)) = N_Abstract_Subprogram_Declaration
424          then
425             Error_Msg_N
426               ("compilation unit cannot be abstract subprogram",
427                  Unit (Comp_Unit_Node));
428
429             Unit_Node :=
430               New_Node (N_Subprogram_Declaration, Sloc (Comp_Unit_Node));
431             Set_Specification (Unit_Node,
432               Specification (Unit (Comp_Unit_Node)));
433             Set_Unit (Comp_Unit_Node, Unit_Node);
434          end if;
435
436       --  Otherwise we have TASK. This is not really an acceptable token,
437       --  but we accept it to improve error recovery.
438
439       elsif Token = Tok_Task then
440          Scan; -- Past TASK
441
442          if Token = Tok_Type then
443             Error_Msg_SP
444               ("task type cannot be used as compilation unit");
445          else
446             Error_Msg_SP
447               ("task declaration cannot be used as compilation unit");
448          end if;
449
450          --  If in check syntax mode, accept the task anyway. This is done
451          --  particularly to improve the behavior of GNATCHOP in this case.
452
453          if Operating_Mode = Check_Syntax then
454             Set_Unit (Comp_Unit_Node, P_Task);
455
456          --  If not in syntax only mode, treat this as horrible error
457
458          else
459             Cunit_Error_Flag := True;
460             return Error;
461          end if;
462
463       else pragma Assert (Token = Tok_Protected);
464          Scan; -- Past PROTECTED
465
466          if Token = Tok_Type then
467             Error_Msg_SP
468               ("protected type cannot be used as compilation unit");
469          else
470             Error_Msg_SP
471               ("protected declaration cannot be used as compilation unit");
472          end if;
473
474          --  If in check syntax mode, accept protected anyway. This is done
475          --  particularly to improve the behavior of GNATCHOP in this case.
476
477          if Operating_Mode = Check_Syntax then
478             Set_Unit (Comp_Unit_Node, P_Protected);
479
480          --  If not in syntax only mode, treat this as horrible error
481
482          else
483             Cunit_Error_Flag := True;
484             return Error;
485          end if;
486       end if;
487
488       --  Here is where locate the compilation unit entity. This is a little
489       --  tricky, since it is buried in various places.
490
491       Unit_Node := Unit (Comp_Unit_Node);
492
493       --  Another error from which it is hard to recover
494
495       if Nkind (Unit_Node) = N_Subprogram_Body_Stub
496         or else Nkind (Unit_Node) = N_Package_Body_Stub
497       then
498          Cunit_Error_Flag := True;
499          return Error;
500       end if;
501
502       --  Only try this if we got an OK unit!
503
504       if Unit_Node /= Error then
505          if Nkind (Unit_Node) = N_Subunit then
506             Unit_Node := Proper_Body (Unit_Node);
507          end if;
508
509          if Nkind (Unit_Node) in N_Generic_Declaration then
510             Unit_Node := Specification (Unit_Node);
511          end if;
512
513          if Nkind (Unit_Node) = N_Package_Declaration
514            or else Nkind (Unit_Node) = N_Subprogram_Declaration
515            or else Nkind (Unit_Node) = N_Subprogram_Body
516            or else Nkind (Unit_Node) = N_Subprogram_Renaming_Declaration
517          then
518             Unit_Node := Specification (Unit_Node);
519
520          elsif Nkind (Unit_Node) = N_Subprogram_Renaming_Declaration then
521             if Ada_Version = Ada_83 then
522                Error_Msg_N
523                  ("(Ada 83) library unit renaming not allowed", Unit_Node);
524             end if;
525          end if;
526
527          if Nkind (Unit_Node) = N_Task_Body
528            or else Nkind (Unit_Node) = N_Protected_Body
529            or else Nkind (Unit_Node) = N_Task_Type_Declaration
530            or else Nkind (Unit_Node) = N_Protected_Type_Declaration
531            or else Nkind (Unit_Node) = N_Single_Task_Declaration
532            or else Nkind (Unit_Node) = N_Single_Protected_Declaration
533          then
534             Name_Node := Defining_Identifier (Unit_Node);
535
536          elsif Nkind (Unit_Node) = N_Function_Instantiation
537            or else Nkind (Unit_Node) = N_Function_Specification
538            or else Nkind (Unit_Node) = N_Generic_Function_Renaming_Declaration
539            or else Nkind (Unit_Node) = N_Generic_Package_Renaming_Declaration
540            or else Nkind (Unit_Node) = N_Generic_Procedure_Renaming_Declaration
541            or else Nkind (Unit_Node) = N_Package_Body
542            or else Nkind (Unit_Node) = N_Package_Instantiation
543            or else Nkind (Unit_Node) = N_Package_Renaming_Declaration
544            or else Nkind (Unit_Node) = N_Package_Specification
545            or else Nkind (Unit_Node) = N_Procedure_Instantiation
546            or else Nkind (Unit_Node) = N_Procedure_Specification
547          then
548             Name_Node := Defining_Unit_Name (Unit_Node);
549
550          --  Anything else is a serious error, abandon scan
551
552          else
553             raise Error_Resync;
554          end if;
555
556          Set_Sloc (Comp_Unit_Node, Sloc (Name_Node));
557          Set_Sloc (Aux_Decls_Node (Comp_Unit_Node), Sloc (Name_Node));
558
559          --  Set Entity field in file table. Easier now that we have name!
560          --  Note that this is also skipped if we had a bad unit
561
562          if Nkind (Name_Node) = N_Defining_Program_Unit_Name then
563             Set_Cunit_Entity
564               (Current_Source_Unit, Defining_Identifier (Name_Node));
565          else
566             Set_Cunit_Entity (Current_Source_Unit, Name_Node);
567          end if;
568
569          Set_Unit_Name
570            (Current_Source_Unit, Get_Unit_Name (Unit (Comp_Unit_Node)));
571
572       --  If we had a bad unit, make sure the fatal flag is set in the file
573       --  table entry, since this is surely a fatal error and also set our
574       --  flag to inhibit the requirement that we be at end of file.
575
576       else
577          Cunit_Error_Flag := True;
578          Set_Fatal_Error (Current_Source_Unit);
579       end if;
580
581       --  Clear away any missing semicolon indication, we are done with that
582       --  unit, so what's done is done, and we don't want anything hanging
583       --  around from the attempt to parse it!
584
585       SIS_Entry_Active := False;
586
587       --  Scan out pragmas after unit
588
589       while Token = Tok_Pragma loop
590          Save_Scan_State (Scan_State);
591
592          --  If we are in syntax scan mode allowing multiple units, then start
593          --  the next unit if we encounter a configuration pragma, or a source
594          --  reference pragma. We take care not to actually scan the pragma in
595          --  this case (we don't want it to take effect for the current unit).
596
597          if Operating_Mode = Check_Syntax then
598             Scan;  -- past Pragma
599
600             if Token = Tok_Identifier
601               and then
602                 (Is_Configuration_Pragma_Name (Token_Name)
603                    or else Token_Name = Name_Source_Reference)
604             then
605                Restore_Scan_State (Scan_State); -- to Pragma
606                exit;
607             end if;
608          end if;
609
610          --  Otherwise eat the pragma, it definitely belongs with the
611          --  current unit, and not with the following unit.
612
613          Restore_Scan_State (Scan_State); -- to Pragma
614          P := P_Pragma;
615
616          if No (Pragmas_After (Aux_Decls_Node (Comp_Unit_Node))) then
617             Set_Pragmas_After
618               (Aux_Decls_Node (Comp_Unit_Node), New_List);
619          end if;
620
621          Append (P, Pragmas_After (Aux_Decls_Node (Comp_Unit_Node)));
622       end loop;
623
624       --  Cancel effect of any outstanding pragma Warnings (Off)
625
626       Set_Warnings_Mode_On (Scan_Ptr);
627
628       --  Ada 83 error checks
629
630       if Ada_Version = Ada_83 then
631
632          --  Check we did not with any child units
633
634          Item := First (Context_Items (Comp_Unit_Node));
635
636          while Present (Item) loop
637             if Nkind (Item) = N_With_Clause
638               and then Nkind (Name (Item)) /= N_Identifier
639             then
640                Error_Msg_N ("(Ada 83) child units not allowed", Item);
641             end if;
642
643             Next (Item);
644          end loop;
645
646          --  Check that we did not have a PRIVATE keyword present
647
648          if Private_Present (Comp_Unit_Node) then
649             Error_Msg
650               ("(Ada 83) private units not allowed", Private_Sloc);
651          end if;
652       end if;
653
654       --  If no serious error, then output possible unit information line
655       --  for gnatchop if we are in syntax only, list units mode.
656
657       if not Cunit_Error_Flag
658         and then List_Units
659         and then Operating_Mode = Check_Syntax
660       then
661          Unit_Display (Comp_Unit_Node, Cunit_Location, SR_Present);
662       end if;
663
664       --  And now we should be at the end of file
665
666       if Token /= Tok_EOF then
667
668          --  If we already had to scan for a compilation unit, then don't
669          --  give any further error message, since it just seems to make
670          --  things worse, and we already gave a serious error message.
671
672          if Cunit_Error_Flag then
673             null;
674
675          --  If we are in check syntax mode, then we allow multiple units
676          --  so we just return with Token not set to Tok_EOF and no message.
677
678          elsif Operating_Mode = Check_Syntax then
679             return Comp_Unit_Node;
680
681          --  We also allow multiple units if we are in multiple unit mode
682
683          elsif Multiple_Unit_Index /= 0 then
684
685             --  Skip tokens to end of file, so that the -gnatl listing
686             --  will be complete in this situation, but no need to parse
687             --  the remaining units; no style checking either.
688
689             declare
690                Save_Style_Check : constant Boolean := Style_Check;
691
692             begin
693                Style_Check := False;
694
695                while Token /= Tok_EOF loop
696                   Scan;
697                end loop;
698
699                Style_Check := Save_Style_Check;
700             end;
701
702             return Comp_Unit_Node;
703
704          --  Otherwise we have an error. We suppress the error message
705          --  if we already had a fatal error, since this stops junk
706          --  cascaded messages in some situations.
707
708          else
709             if not Fatal_Error (Current_Source_Unit) then
710                if Token in Token_Class_Cunit then
711                   Error_Msg_SC
712                     ("end of file expected, " &
713                      "file can have only one compilation unit");
714                else
715                   Error_Msg_SC ("end of file expected");
716                end if;
717             end if;
718          end if;
719
720          --  Skip tokens to end of file, so that the -gnatl listing
721          --  will be complete in this situation, but no error checking
722          --  other than that provided at the token level.
723
724          while Token /= Tok_EOF loop
725             Scan;
726          end loop;
727
728          return Error;
729
730       --  Normal return (we were at the end of file as expected)
731
732       else
733          return Comp_Unit_Node;
734       end if;
735
736    exception
737
738       --  An error resync is a serious bomb, so indicate result unit no good
739
740       when Error_Resync =>
741          Set_Fatal_Error (Current_Source_Unit);
742          return Error;
743    end P_Compilation_Unit;
744
745    --------------------------
746    -- 10.1.1  Library Item --
747    --------------------------
748
749    --  Parsed by P_Compilation_Unit (10.1.1)
750
751    --------------------------------------
752    -- 10.1.1  Library Unit Declaration --
753    --------------------------------------
754
755    --  Parsed by P_Compilation_Unit (10.1.1)
756
757    ------------------------------------------------
758    -- 10.1.1  Library Unit Renaming Declaration  --
759    ------------------------------------------------
760
761    --  Parsed by P_Compilation_Unit (10.1.1)
762
763    -------------------------------
764    -- 10.1.1  Library Unit Body --
765    -------------------------------
766
767    --  Parsed by P_Compilation_Unit (10.1.1)
768
769    ------------------------------
770    -- 10.1.1  Parent Unit Name --
771    ------------------------------
772
773    --  Parsed (as a name) by its parent construct
774
775    ----------------------------
776    -- 10.1.2  Context Clause --
777    ----------------------------
778
779    --  CONTEXT_CLAUSE ::= {CONTEXT_ITEM}
780
781    --  CONTEXT_ITEM ::= WITH_CLAUSE | USE_CLAUSE | WITH_TYPE_CLAUSE
782
783    --  WITH_CLAUSE ::=
784    --  [LIMITED] [PRIVATE]  with library_unit_NAME {,library_unit_NAME};
785    --  Note: the two qualifiers are Ada 2005 extensions.
786
787    --  WITH_TYPE_CLAUSE ::=
788    --    with type type_NAME is access; | with type type_NAME is tagged;
789    --  Note: this form is obsolete (old GNAT extension).
790
791    --  Error recovery: Cannot raise Error_Resync
792
793    function P_Context_Clause return List_Id is
794       Item_List   : List_Id;
795       Has_Limited : Boolean := False;
796       Has_Private : Boolean := False;
797       Scan_State  : Saved_Scan_State;
798       With_Node   : Node_Id;
799       First_Flag  : Boolean;
800
801    begin
802       Item_List := New_List;
803
804       --  Get keyword casing from WITH keyword in case not set yet
805
806       if Token = Tok_With then
807          Set_Keyword_Casing (Current_Source_File, Determine_Token_Casing);
808       end if;
809
810       --  Loop through context items
811
812       loop
813          if Style_Check then
814             Style.Check_Indentation;
815          end if;
816
817          --  Gather any pragmas appearing in the context clause
818
819          P_Pragmas_Opt (Item_List);
820
821          --  Processing for WITH clause
822
823          --  Ada 2005 (AI-50217, AI-262): First check for LIMITED WITH,
824          --  PRIVATE WITH, or both.
825
826          if Token = Tok_Limited then
827             Has_Limited := True;
828             Has_Private := False;
829             Scan; -- past LIMITED
830
831             --  In the context, LIMITED can only appear in a with_clause
832
833             if Token = Tok_Private then
834                Has_Private := True;
835                Scan;  -- past PRIVATE
836             end if;
837
838             if Token /= Tok_With then
839                Error_Msg_SC ("unexpected LIMITED ignored");
840             end if;
841
842             if Ada_Version < Ada_05 then
843                Error_Msg_SP ("LIMITED WITH is an Ada 2005 extension");
844                Error_Msg_SP
845                  ("\unit must be compiled with -gnat05 switch");
846             end if;
847
848          elsif Token = Tok_Private then
849             Has_Limited := False;
850             Has_Private := True;
851             Save_Scan_State (Scan_State);
852             Scan;  -- past PRIVATE
853
854             if Token /= Tok_With then
855
856                --  Keyword is beginning of private child unit
857
858                Restore_Scan_State (Scan_State); -- to PRIVATE
859                return Item_List;
860
861             elsif Ada_Version < Ada_05 then
862                Error_Msg_SP ("`PRIVATE WITH` is an Ada 2005 extension");
863                Error_Msg_SP
864                  ("\unit must be compiled with -gnat05 switch");
865             end if;
866
867          else
868             Has_Limited := False;
869             Has_Private := False;
870          end if;
871
872          if Token = Tok_With then
873             Scan; -- past WITH
874
875             if Token = Tok_Type then
876
877                --  WITH TYPE is an obsolete GNAT specific extension
878
879                Error_Msg_SP
880                  ("`WITH TYPE` is an obsolete 'G'N'A'T extension");
881                Error_Msg_SP ("\use Ada 2005 `LIMITED WITH` clause instead");
882
883                Scan;  -- past TYPE
884
885                T_Is;
886
887                if Token = Tok_Tagged then
888                   Scan;
889
890                elsif Token = Tok_Access then
891                   Scan;
892
893                else
894                   Error_Msg_SC ("expect tagged or access qualifier");
895                end if;
896
897                TF_Semicolon;
898
899             else
900                First_Flag := True;
901
902                --  Loop through names in one with clause, generating a separate
903                --  N_With_Clause node for each name encountered.
904
905                loop
906                   With_Node := New_Node (N_With_Clause, Token_Ptr);
907                   Append (With_Node, Item_List);
908
909                   --  Note that we allow with'ing of child units, even in
910                   --  Ada 83 mode, since presumably if this is not desired,
911                   --  then the compilation of the child unit itself is the
912                   --  place where such an "error" should be caught.
913
914                   Set_Name (With_Node, P_Qualified_Simple_Name);
915                   Set_First_Name (With_Node, First_Flag);
916                   Set_Limited_Present (With_Node, Has_Limited);
917                   Set_Private_Present (With_Node, Has_Private);
918                   First_Flag := False;
919
920                   --  All done if no comma
921
922                   exit when Token /= Tok_Comma;
923
924                   --  If comma is followed by compilation unit token
925                   --  or by USE, or PRAGMA, then it should have been a
926                   --  semicolon after all
927
928                   Save_Scan_State (Scan_State);
929                   Scan; -- past comma
930
931                   if Token in Token_Class_Cunit
932                     or else Token = Tok_Use
933                     or else Token = Tok_Pragma
934                   then
935                      Restore_Scan_State (Scan_State);
936                      exit;
937                   end if;
938                end loop;
939
940                Set_Last_Name (With_Node, True);
941                TF_Semicolon;
942             end if;
943
944          --  Processing for USE clause
945
946          elsif Token = Tok_Use then
947             Append (P_Use_Clause, Item_List);
948
949          --  Anything else is end of context clause
950
951          else
952             exit;
953          end if;
954       end loop;
955
956       return Item_List;
957    end P_Context_Clause;
958
959    --------------------------
960    -- 10.1.2  Context Item --
961    --------------------------
962
963    --  Parsed by P_Context_Clause (10.1.2)
964
965    -------------------------
966    -- 10.1.2  With Clause --
967    -------------------------
968
969    --  Parsed by P_Context_Clause (10.1.2)
970
971    -----------------------
972    -- 10.1.3  Body Stub --
973    -----------------------
974
975    --  Subprogram stub parsed by P_Subprogram (6.1)
976    --  Package stub parsed by P_Package (7.1)
977    --  Task stub parsed by P_Task (9.1)
978    --  Protected stub parsed by P_Protected (9.4)
979
980    ----------------------------------
981    -- 10.1.3  Subprogram Body Stub --
982    ----------------------------------
983
984    --  Parsed by P_Subprogram (6.1)
985
986    -------------------------------
987    -- 10.1.3  Package Body Stub --
988    -------------------------------
989
990    --  Parsed by P_Package (7.1)
991
992    ----------------------------
993    -- 10.1.3  Task Body Stub --
994    ----------------------------
995
996    --  Parsed by P_Task (9.1)
997
998    ---------------------------------
999    -- 10.1.3  Protected Body Stub --
1000    ---------------------------------
1001
1002    --  Parsed by P_Protected (9.4)
1003
1004    ---------------------
1005    -- 10.1.3  Subunit --
1006    ---------------------
1007
1008    --  SUBUNIT ::= separate (PARENT_UNIT_NAME) PROPER_BODY
1009
1010    --  PARENT_UNIT_NAME ::= NAME
1011
1012    --  The caller has checked that the initial token is SEPARATE
1013
1014    --  Error recovery: cannot raise Error_Resync
1015
1016    function P_Subunit return Node_Id is
1017       Subunit_Node : Node_Id;
1018       Body_Node    : Node_Id;
1019
1020    begin
1021       Subunit_Node := New_Node (N_Subunit, Token_Ptr);
1022       Body_Node := Error; -- in case no good body found
1023       Scan; -- past SEPARATE;
1024
1025       U_Left_Paren;
1026       Set_Name (Subunit_Node, P_Qualified_Simple_Name);
1027       U_Right_Paren;
1028
1029       Ignore (Tok_Semicolon);
1030
1031       if Token = Tok_Function or else Token = Tok_Procedure then
1032          Body_Node := P_Subprogram (Pf_Pbod);
1033
1034       elsif Token = Tok_Package then
1035          Body_Node := P_Package (Pf_Pbod);
1036
1037       elsif Token = Tok_Protected then
1038          Scan; -- past PROTECTED
1039
1040          if Token = Tok_Body then
1041             Body_Node := P_Protected;
1042          else
1043             Error_Msg_AP ("BODY expected");
1044             return Error;
1045          end if;
1046
1047       elsif Token = Tok_Task then
1048          Scan; -- past TASK
1049
1050          if Token = Tok_Body then
1051             Body_Node := P_Task;
1052          else
1053             Error_Msg_AP ("BODY expected");
1054             return Error;
1055          end if;
1056
1057       else
1058          Error_Msg_SC ("proper body expected");
1059          return Error;
1060       end if;
1061
1062       Set_Proper_Body  (Subunit_Node, Body_Node);
1063       return Subunit_Node;
1064    end P_Subunit;
1065
1066    ------------------
1067    -- Set_Location --
1068    ------------------
1069
1070    function Set_Location return Source_Ptr is
1071       Physical   : Boolean;
1072       Loc        : Source_Ptr;
1073       Scan_State : Saved_Scan_State;
1074
1075    begin
1076       --  A special check. If the first token is pragma, and this is a
1077       --  Source_Reference pragma, then do NOT eat previous comments, since
1078       --  the Source_Reference pragma is required to be the first line in
1079       --  the source file.
1080
1081       if Token = Tok_Pragma then
1082          Save_Scan_State (Scan_State);
1083          Scan; --  past Pragma
1084
1085          if Token = Tok_Identifier
1086            and then Token_Name = Name_Source_Reference
1087          then
1088             Restore_Scan_State (Scan_State);
1089             return Token_Ptr;
1090          end if;
1091
1092          Restore_Scan_State (Scan_State);
1093       end if;
1094
1095       --  Otherwise acquire previous comments and blank lines
1096
1097       if Prev_Token = No_Token then
1098          return Source_First (Current_Source_File);
1099
1100       else
1101          Loc := Prev_Token_Ptr;
1102          loop
1103             exit when Loc = Token_Ptr;
1104
1105             --  Should we worry about UTF_32 line terminators here
1106
1107             if Source (Loc) in Line_Terminator then
1108                Skip_Line_Terminators (Loc, Physical);
1109                exit when Physical;
1110             end if;
1111
1112             Loc := Loc + 1;
1113          end loop;
1114
1115          return Loc;
1116       end if;
1117    end Set_Location;
1118
1119    ------------------
1120    -- Unit_Display --
1121    ------------------
1122
1123    --  The format of the generated line, as expected by GNATCHOP is
1124
1125    --    Unit {unit} line {line}, file offset {offs} [, SR], file name {file}
1126
1127    --  where
1128
1129    --     {unit}     unit name with terminating (spec) or (body)
1130    --     {line}     starting line number
1131    --     {offs}     offset to start of text in file
1132    --     {file}     source file name
1133
1134    --  The SR parameter is present only if a source reference pragma was
1135    --  scanned for this unit. The significance is that gnatchop should not
1136    --  attempt to add another one.
1137
1138    procedure Unit_Display
1139      (Cunit      : Node_Id;
1140       Loc        : Source_Ptr;
1141       SR_Present : Boolean)
1142    is
1143       Unum : constant Unit_Number_Type    := Get_Cunit_Unit_Number (Cunit);
1144       Sind : constant Source_File_Index   := Source_Index (Unum);
1145       Unam : constant Unit_Name_Type      := Unit_Name (Unum);
1146
1147    begin
1148       if List_Units then
1149          Write_Str ("Unit ");
1150          Write_Unit_Name (Unit_Name (Unum));
1151          Unit_Location (Sind, Loc);
1152
1153          if SR_Present then
1154             Write_Str (", SR");
1155          end if;
1156
1157          Write_Str (", file name ");
1158          Write_Name (Get_File_Name (Unam, Nkind (Unit (Cunit)) = N_Subunit));
1159          Write_Eol;
1160       end if;
1161    end Unit_Display;
1162
1163    -------------------
1164    -- Unit_Location --
1165    -------------------
1166
1167    procedure Unit_Location (Sind : Source_File_Index; Loc : Source_Ptr) is
1168       Line : constant Logical_Line_Number := Get_Logical_Line_Number (Loc);
1169       --  Should the above be the physical line number ???
1170
1171    begin
1172       Write_Str (" line ");
1173       Write_Int (Int (Line));
1174
1175       Write_Str (", file offset ");
1176       Write_Int (Int (Loc) - Int (Source_First (Sind)));
1177    end Unit_Location;
1178
1179 end Ch10;