OSDN Git Service

Licensing changes to GPLv3 resp. GPLv3 with GCC Runtime Exception.
[pf3gnuchains/gcc-fork.git] / gcc / ada / lib.ads
1 ------------------------------------------------------------------------------
2 --                                                                          --
3 --                         GNAT COMPILER COMPONENTS                         --
4 --                                                                          --
5 --                                  L I B                                   --
6 --                                                                          --
7 --                                 S p e c                                  --
8 --                                                                          --
9 --          Copyright (C) 1992-2009, Free Software Foundation, Inc.         --
10 --                                                                          --
11 -- GNAT is free software;  you can  redistribute it  and/or modify it under --
12 -- terms of the  GNU General Public License as published  by the Free Soft- --
13 -- ware  Foundation;  either version 3,  or (at your option) any later ver- --
14 -- sion.  GNAT is distributed in the hope that it will be useful, but WITH- --
15 -- OUT ANY WARRANTY;  without even the  implied warranty of MERCHANTABILITY --
16 -- or FITNESS FOR A PARTICULAR PURPOSE.                                     --
17 --                                                                          --
18 -- As a special exception under Section 7 of GPL version 3, you are granted --
19 -- additional permissions described in the GCC Runtime Library Exception,   --
20 -- version 3.1, as published by the Free Software Foundation.               --
21 --                                                                          --
22 -- You should have received a copy of the GNU General Public License and    --
23 -- a copy of the GCC Runtime Library Exception along with this program;     --
24 -- see the files COPYING3 and COPYING.RUNTIME respectively.  If not, see    --
25 -- <http://www.gnu.org/licenses/>.                                          --
26 --                                                                          --
27 -- GNAT was originally developed  by the GNAT team at  New York University. --
28 -- Extensive contributions were provided by Ada Core Technologies Inc.      --
29 --                                                                          --
30 ------------------------------------------------------------------------------
31
32 --  This package contains routines for accessing and outputting the library
33 --  information. It contains the routine to load subsidiary units.
34
35 with Alloc;
36 with Namet; use Namet;
37 with Table;
38 with Types; use Types;
39
40 package Lib is
41
42    --------------------------------------------
43    -- General Approach to Library Management --
44    --------------------------------------------
45
46    --  As described in GNote #1, when a unit is compiled, all its subsidiary
47    --  units are recompiled, including the following:
48
49    --    (a) Corresponding spec for a body
50    --    (b) Parent spec of a child library spec
51    --    (d) With'ed specs
52    --    (d) Parent body of a subunit
53    --    (e) Subunits corresponding to any specified stubs
54    --    (f) Bodies of inlined subprograms that are called
55    --    (g) Bodies of generic subprograms or packages that are instantiated
56    --    (h) Bodies of packages containing either of the above two items
57    --    (i) Specs and bodies of runtime units
58    --    (j) Parent specs for with'ed child library units
59
60    --  If a unit is being compiled only for syntax checking, then no subsidiary
61    --  units are loaded, the syntax check applies only to the main unit,
62    --  i.e. the one contained in the source submitted to the library.
63
64    --  If a unit is being compiled for syntax and semantic checking, then only
65    --  cases (a)-(d) loads are performed, since the full semantic checking can
66    --  be carried out without needing (e)-(i) loads. In this case no object
67    --  file, or library information file, is generated, so the missing units
68    --  do not affect the results.
69
70    --  Specifications of library subprograms, subunits, and generic specs
71    --  and bodies, can only be compiled in syntax/semantic checking mode,
72    --  since no code is ever generated directly for these units. In the case
73    --  of subunits, only the compilation of the ultimate parent unit generates
74    --  actual code. If a subunit is submitted to the compiler in syntax/
75    --  semantic checking mode, the parent (or parents in the nested case) are
76    --  semantically checked only up to the point of the corresponding stub.
77
78    --  If code is being generated, then all the above units are required,
79    --  although the need for bodies of inlined procedures can be suppressed
80    --  by the use of a switch that sets the mode to ignore pragma Inline
81    --  statements.
82
83    --  The two main sections of the front end, Par and Sem, are recursive.
84    --  Compilation proceeds unit by unit making recursive calls as necessary.
85    --  The process is controlled from the GNAT main program, which makes calls
86    --  to Par and Sem sequence for the main unit.
87
88    --  Par parses the given unit, and then, after the parse is complete, uses
89    --  the Par.Load subprogram to load all its subsidiary units in categories
90    --  (a)-(d) above, installing pointers to the loaded units in the parse
91    --  tree, as described in a later section of this spec. If any of these
92    --  required units is missing, a fatal error is signalled, so that no
93    --  attempt is made to run Sem in such cases, since it is assumed that
94    --  too many cascaded errors would result, and the confusion would not
95    --  be helpful.
96
97    --  Following the call to Par on the main unit, the entire tree of required
98    --  units is thus loaded, and Sem is called on the main unit. The parameter
99    --  passed to Sem is the unit to be analyzed. The visibility table, which
100    --  is a single global structure, starts out containing only the entries
101    --  for the visible entities in Standard. Every call to Sem establishes a
102    --  new scope stack table, pushing an entry for Standard on entry to provide
103    --  the proper initial scope environment.
104
105    --  Sem first proceeds to perform semantic analysis on the currently loaded
106    --  units as follows:
107
108    --    In the case of a body (case (a) above), Sem analyzes the corresponding
109    --    spec, using a recursive call to Sem. As is always expected to be the
110    --    case with calls to Sem, any entities installed in the visibility table
111    --    are removed on exit from Sem, so that these entities have to be
112    --    reinstalled on return to continue the analysis of the body which of
113    --    course needs visibility of these entities.
114    --
115    --    In the case of the parent of a child spec (case (b) above), a similar
116    --    call is made to Sem to analyze the parent. Again, on return, the
117    --    entities from the analyzed parent spec have to be installed in the
118    --    visibility table of the caller (the child unit), which must have
119    --    visibility to the entities in its parent spec.
120
121    --    For with'ed specs (case (c) above), a recursive call to Sem is made
122    --    to analyze each spec in turn. After all the spec's have been analyzed,
123    --    but not till that point, the entities from all the with'ed units are
124    --    reinstalled in the visibility table so that the caller can proceed
125    --    with the analysis of the unit doing the with's with the necessary
126    --    entities made either potentially use visible or visible by selection
127    --    as needed.
128
129    --    Case (d) arises when Sem is passed a subunit to analyze. This means
130    --    that the main unit is a subunit, and the unit passed to Sem is either
131    --    the main unit, or one of its ancestors that is still a subunit. Since
132    --    analysis must start at the top of the tree, Sem essentially cancels
133    --    the current call by immediately making a call to analyze the parent
134    --    (when this call is finished it immediately returns, so logically this
135    --    call is like a goto). The subunit will then be analyzed at the proper
136    --    time as described for the stub case. Note that we also turn off the
137    --    indication that code should be generated in this case, since the only
138    --    time we generate code for subunits is when compiling the main parent.
139
140    --    Case (e), subunits corresponding to stubs, are handled as the stubs
141    --    are encountered. There are three sub-cases:
142
143    --      If the subunit has already been loaded, then this means that the
144    --      main unit was a subunit, and we are back on our way down to it
145    --      after following the initial processing described for case (d).
146    --      In this case we analyze this particular subunit, as described
147    --      for the case where we are generating code, but when we get back
148    --      we are all done, since the rest of the parent is irrelevant. To
149    --      get out of the parent, we raise the exception Subunit_Found, which
150    --      is handled at the outer level of Sem.
151
152    --      The cases where the subunit has not already been loaded correspond
153    --      to cases where the main unit was a parent. In this case the action
154    --      depends on whether or not we are generating code. If we are not
155    --      generating code, then this is the case where we can simply ignore
156    --      the subunit, since in checking mode we don't even want to insist
157    --      that the subunit exist, much less waste time checking it.
158
159    --      If we are generating code, then we need to load and analyze
160    --      all subunits. This is achieved with a call to Lib.Load to load
161    --      and parse the unit, followed by processing that installs the
162    --      context clause of the subunit, analyzes the subunit, and then
163    --      removes the context clause (from the visibility chains of the
164    --      parent). Note that we do *not* do a recursive call to Sem in
165    --      this case, precisely because we need to do the analysis of the
166    --      subunit with the current visibility table and scope stack.
167
168    --    Case (f) applies only to subprograms for which a pragma Inline is
169    --    given, providing that the compiler is operating in the mode where
170    --    pragma Inline's are activated. When the expander encounters a call
171    --    to such a subprogram, it loads the body of the subprogram if it has
172    --    not already been loaded, and calls Sem to process it.
173
174    --    Case (g) is similar to case (f), except that the body of a generic
175    --    is unconditionally required, regardless of compiler mode settings.
176    --    As in the subprogram case, when the expander encounters a generic
177    --    instantiation, it loads the generic body of the subprogram if it
178    --    has not already been loaded, and calls Sem to process it.
179
180    --    Case (h) arises when a package contains either an inlined subprogram
181    --    which is called, or a generic which is instantiated. In this case the
182    --    body of the package must be loaded and analyzed with a call to Sem.
183
184    --    Case (i) is handled by adding implicit with clauses to the context
185    --    clauses of all units that potentially reference the relevant runtime
186    --    entities. Note that since we have the full set of units available,
187    --    the parser can always determine the set of runtime units that is
188    --    needed. These with clauses do not have associated use clauses, so
189    --    all references to the entities must be by selection. Once the with
190    --    clauses have been added, subsequent processing is as for normal
191    --    with clauses.
192
193    --    Case (j) is also handled by adding appropriate implicit with clauses
194    --    to any unit that withs a child unit. Again there is no use clause,
195    --    and subsequent processing proceeds as for an explicit with clause.
196
197    --  Sem thus completes the loading of all required units, except those
198    --  required for inline subprogram bodies or inlined generics. If any
199    --  of these load attempts fails, then the expander will not be called,
200    --  even if code was to be generated. If the load attempts all succeed
201    --  then the expander is called, though the attempt to generate code may
202    --  still fail if an error occurs during a load attempt for an inlined
203    --  body or a generic body.
204
205    -------------------------------------------
206    -- Special Handling of Subprogram Bodies --
207    -------------------------------------------
208
209    --  A subprogram body (in an adb file) may stand for both a spec and a body.
210    --  A simple model (and one that was adopted through version 2.07) is simply
211    --  to assume that such an adb file acts as its own spec if no ads file is
212    --  is present.
213
214    --  However, this is not correct. RM 10.1.4(4) requires that such a body
215    --  act as a spec unless a subprogram declaration of the same name is
216    --  already present. The correct interpretation of this in GNAT library
217    --  terms is to ignore an existing ads file of the same name unless this
218    --  ads file contains a subprogram declaration with the same name.
219
220    --  If there is an ads file with a unit other than a subprogram declaration
221    --  with the same name, then a fatal message is output, noting that this
222    --  irrelevant file must be deleted before the body can be compiled. See
223    --  ACVC test CA1020D to see how this processing is required.
224
225    -----------------
226    -- Global Data --
227    -----------------
228
229    Current_Sem_Unit : Unit_Number_Type := Main_Unit;
230    --  Unit number of unit currently being analyzed/expanded. This is set when
231    --  ever a new unit is entered, saving and restoring the old value, so that
232    --  it always reflects the unit currently being analyzed. The initial value
233    --  of Main_Unit ensures that a proper value is set initially, and in
234    --  particular for analysis of configuration pragmas in gnat.adc.
235
236    Main_Unit_Entity : Entity_Id;
237    --  Entity of main unit, same as Cunit_Entity (Main_Unit) except where
238    --  Main_Unit is a body with a separate spec, in which case it is the
239    --  entity for the spec.
240
241    -----------------
242    -- Units Table --
243    -----------------
244
245    --  The units table has an entry for each unit (source file) read in by the
246    --  current compilation. The table is indexed by the unit number value,
247    --  The first entry in the table, subscript Main_Unit, is for the main file.
248    --  Each entry in this units table contains the following data.
249
250    --    Unit_File_Name
251    --      The name of the source file containing the unit. Set when the entry
252    --      is created by a call to Lib.Load, and then cannot be changed.
253
254    --    Source_Index
255    --      The index in the source file table of the corresponding source file.
256    --      Set when the entry is created by a call to Lib.Load and then cannot
257    --      be changed.
258
259    --    Munit_Index
260    --      The index of the unit within the file for multiple unit per file
261    --      mode. Set to zero in normal single unit per file mode.
262
263    --    Error_Location
264    --      This is copied from the Sloc field of the Enode argument passed
265    --      to Load_Unit. It refers to the enclosing construct which caused
266    --      this unit to be loaded, e.g. most typically the with clause that
267    --      referenced the unit, and is used for error handling in Par.Load.
268
269    --    Expected_Unit
270    --      This is the expected unit name for a file other than the main unit,
271    --      since these are cases where we load the unit using Lib.Load and we
272    --      know the unit that is expected. It must be the same as Unit_Name
273    --      if it is set (see test in Par.Load). Expected_Unit is set to
274    --      No_Name for the main unit.
275
276    --    Unit_Name
277    --      The name of the unit. Initialized to No_Name by Lib.Load, and then
278    --      set by the parser when the unit is parsed to the unit name actually
279    --      found in the file (which should, in the absence of errors) be the
280    --      same name as Expected_Unit.
281
282    --    Cunit
283    --      Pointer to the N_Compilation_Unit node. Initially set to Empty by
284    --      Lib.Load, and then reset to the required node by the parser when
285    --      the unit is parsed.
286
287    --    Cunit_Entity
288    --      Pointer to the entity node for the compilation unit. Initially set
289    --      to Empty by Lib.Load, and then reset to the required entity by the
290    --      parser when the unit is parsed.
291
292    --    Dependency_Num
293    --      This is the number of the unit within the generated dependency
294    --      lines (D lines in the ALI file) which are sorted into alphabetical
295    --      order. The number is ones origin, so a value of 2 refers to the
296    --      second generated D line. The Dependency_Number values are set
297    --      as the D lines are generated, and are used to generate proper
298    --      unit references in the generated xref information.
299
300    --    Dynamic_Elab
301    --      A flag indicating if this unit was compiled with dynamic elaboration
302    --      checks specified (as the result of using the -gnatE compilation
303    --      option or a pragma Elaboration_Checks (Dynamic).
304
305    --    Fatal_Error
306    --      A flag that is initialized to False, and gets set to True if a fatal
307    --      error occurs during the processing of a unit. A fatal error is one
308    --      defined as serious enough to stop the next phase of the compiler
309    --      from running (i.e. fatal error during parsing stops semantics,
310    --      fatal error during semantics stops code generation). Note that
311    --      currently, errors of any kind cause Fatal_Error to be set, but
312    --      eventually perhaps only errors labeled as Fatal_Errors should be
313    --      this severe if we decide to try Sem on sources with minor errors.
314
315    --    Generate_Code
316    --      This flag is set True for all units in the current file for which
317    --      code is to be generated. This includes the unit explicitly compiled,
318    --      together with its specification, and any subunits.
319
320    --    Has_RACW
321    --      A Boolean flag, initially set to False when a unit entry is created,
322    --      and set to True if the unit defines a remote access to class wide
323    --      (RACW) object. This is used for controlling generation of the RA
324    --      attribute in the ali file.
325
326    --    Is_Compiler_Unit
327    --      A Boolean flag, initially set False by default, set to True if a
328    --      pragma Compiler_Unit appears in the unit.
329
330    --    Ident_String
331    --      N_String_Literal node from a valid pragma Ident that applies to
332    --      this unit. If no Ident pragma applies to the unit, then Empty.
333
334    --    Loading
335    --      A flag that is used to catch circular WITH dependencies. It is set
336    --      True when an entry is initially created in the file table, and set
337    --      False when the load is completed, or ends with an error.
338
339    --    Main_Priority
340    --      This field is used to indicate the priority of a possible main
341    --      program, as set by a pragma Priority. A value of -1 indicates
342    --      that the default priority is to be used (and is also used for
343    --      entries that do not correspond to possible main programs).
344
345    --    OA_Setting
346    --      This is a character field containing L if Optimize_Alignment mode
347    --      was set locally, and O/T/S for Off/Time/Space default if not.
348
349    --    Serial_Number
350    --      This field holds a serial number used by New_Internal_Name to
351    --      generate unique temporary numbers on a unit by unit basis. The
352    --      only access to this field is via the Increment_Serial_Number
353    --      routine which increments the current value and returns it. This
354    --      serial number is separate for each unit.
355
356    --    Version
357    --      This field holds the version of the unit, which is computed as
358    --      the exclusive or of the checksums of this unit, and all its
359    --      semantically dependent units. Access to the version number field
360    --      is not direct, but is done through the routines described below.
361    --      When a unit table entry is created, this field is initialized to
362    --      the checksum of the corresponding source file. Version_Update is
363    --      then called to reflect the contributions of any unit on which this
364    --      unit is semantically dependent.
365
366    --  The units table is reset to empty at the start of the compilation of
367    --  each main unit by Lib.Initialize. Entries are then added by calls to
368    --  the Lib.Load procedure. The following subprograms are used to access
369    --  and modify entries in the Units table. Individual entries are accessed
370    --  using a unit number value which ranges from Main_Unit (the first entry,
371    --  which is always for the current main unit) to Last_Unit.
372
373    Default_Main_Priority : constant Int := -1;
374    --  Value used in Main_Priority field to indicate default main priority
375
376    function Cunit            (U : Unit_Number_Type) return Node_Id;
377    function Cunit_Entity     (U : Unit_Number_Type) return Entity_Id;
378    function Dependency_Num   (U : Unit_Number_Type) return Nat;
379    function Dynamic_Elab     (U : Unit_Number_Type) return Boolean;
380    function Error_Location   (U : Unit_Number_Type) return Source_Ptr;
381    function Expected_Unit    (U : Unit_Number_Type) return Unit_Name_Type;
382    function Fatal_Error      (U : Unit_Number_Type) return Boolean;
383    function Generate_Code    (U : Unit_Number_Type) return Boolean;
384    function Ident_String     (U : Unit_Number_Type) return Node_Id;
385    function Has_RACW         (U : Unit_Number_Type) return Boolean;
386    function Is_Compiler_Unit (U : Unit_Number_Type) return Boolean;
387    function Loading          (U : Unit_Number_Type) return Boolean;
388    function Main_Priority    (U : Unit_Number_Type) return Int;
389    function Munit_Index      (U : Unit_Number_Type) return Nat;
390    function OA_Setting       (U : Unit_Number_Type) return Character;
391    function Source_Index     (U : Unit_Number_Type) return Source_File_Index;
392    function Unit_File_Name   (U : Unit_Number_Type) return File_Name_Type;
393    function Unit_Name        (U : Unit_Number_Type) return Unit_Name_Type;
394    --  Get value of named field from given units table entry
395
396    procedure Set_Cunit            (U : Unit_Number_Type; N : Node_Id);
397    procedure Set_Cunit_Entity     (U : Unit_Number_Type; E : Entity_Id);
398    procedure Set_Dynamic_Elab     (U : Unit_Number_Type; B : Boolean := True);
399    procedure Set_Error_Location   (U : Unit_Number_Type; W : Source_Ptr);
400    procedure Set_Fatal_Error      (U : Unit_Number_Type; B : Boolean := True);
401    procedure Set_Generate_Code    (U : Unit_Number_Type; B : Boolean := True);
402    procedure Set_Has_RACW         (U : Unit_Number_Type; B : Boolean := True);
403    procedure Set_Is_Compiler_Unit (U : Unit_Number_Type; B : Boolean := True);
404    procedure Set_Ident_String     (U : Unit_Number_Type; N : Node_Id);
405    procedure Set_Loading          (U : Unit_Number_Type; B : Boolean := True);
406    procedure Set_Main_Priority    (U : Unit_Number_Type; P : Int);
407    procedure Set_OA_Setting       (U : Unit_Number_Type; C : Character);
408    procedure Set_Unit_Name        (U : Unit_Number_Type; N : Unit_Name_Type);
409    --  Set value of named field for given units table entry. Note that we
410    --  do not have an entry for each possible field, since some of the fields
411    --  can only be set by specialized interfaces (defined below).
412
413    function Version_Get (U : Unit_Number_Type) return Word_Hex_String;
414    --  Returns the version as a string with 8 hex digits (upper case letters)
415
416    function Last_Unit return Unit_Number_Type;
417    --  Unit number of last allocated unit
418
419    function Num_Units return Nat;
420    --  Number of units currently in unit table
421
422    procedure Remove_Unit (U : Unit_Number_Type);
423    --  Remove unit U from unit table. Currently this is effective only
424    --  if U is the last unit currently stored in the unit table.
425
426    function Entity_Is_In_Main_Unit (E : Entity_Id) return Boolean;
427    --  Returns True if the entity E is declared in the main unit, or, in
428    --  its corresponding spec, or one of its subunits. Entities declared
429    --  within generic instantiations return True if the instantiation is
430    --  itself "in the main unit" by this definition. Otherwise False.
431
432    function Get_Source_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type;
433    pragma Inline (Get_Source_Unit);
434    function Get_Source_Unit (S : Source_Ptr) return Unit_Number_Type;
435    --  Return unit number of file identified by given source pointer value.
436    --  This call must always succeed, since any valid source pointer value
437    --  belongs to some previously loaded module. If the given source pointer
438    --  value is within an instantiation, this function returns the unit number
439    --  of the template, i.e. the unit containing the source code corresponding
440    --  to the given Source_Ptr value. The version taking a Node_Id argument, N,
441    --  simply applies the function to Sloc (N).
442
443    function Get_Code_Unit (N : Node_Or_Entity_Id) return Unit_Number_Type;
444    pragma Inline (Get_Code_Unit);
445    function Get_Code_Unit (S : Source_Ptr) return Unit_Number_Type;
446    --  This is like Get_Source_Unit, except that in the instantiation case,
447    --  it uses the location of the top level instantiation, rather than the
448    --  template, so it returns the unit number containing the code that
449    --  corresponds to the node N, or the source location S.
450
451    function In_Same_Source_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
452    pragma Inline (In_Same_Source_Unit);
453    --  Determines if the two nodes or entities N1 and N2 are in the same
454    --  source unit, the criterion being that Get_Source_Unit yields the
455    --  same value for each argument.
456
457    function In_Same_Code_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
458    pragma Inline (In_Same_Code_Unit);
459    --  Determines if the two nodes or entities N1 and N2 are in the same
460    --  code unit, the criterion being that Get_Code_Unit yields the same
461    --  value for each argument.
462
463    function In_Same_Extended_Unit (N1, N2 : Node_Or_Entity_Id) return Boolean;
464    pragma Inline (In_Same_Extended_Unit);
465    --  Determines if two nodes or entities N1 and N2 are in the same
466    --  extended unit, where an extended unit is defined as a unit and all
467    --  its subunits (considered recursively, i.e. subunits of subunits are
468    --  included). Returns true if S1 and S2 are in the same extended unit
469    --  and False otherwise.
470
471    function In_Same_Extended_Unit (S1, S2 : Source_Ptr) return Boolean;
472    pragma Inline (In_Same_Extended_Unit);
473    --  Determines if the two source locations S1 and S2 are in the same
474    --  extended unit, where an extended unit is defined as a unit and all
475    --  its subunits (considered recursively, i.e. subunits of subunits are
476    --  included). Returns true if S1 and S2 are in the same extended unit
477    --  and False otherwise.
478
479    function In_Extended_Main_Code_Unit
480      (N : Node_Or_Entity_Id) return Boolean;
481    --  Return True if the node is in the generated code of the extended main
482    --  unit, defined as the main unit, its specification (if any), and all
483    --  its subunits (considered recursively). Units for which this enquiry
484    --  returns True are those for which code will be generated. Nodes from
485    --  instantiations are included in the extended main unit for this call.
486    --  If the main unit is itself a subunit, then the extended main unit
487    --  includes its parent unit, and the parent unit spec if it is separate.
488
489    function In_Extended_Main_Code_Unit (Loc : Source_Ptr) return Boolean;
490    --  Same function as above, but argument is a source pointer rather
491    --  than a node.
492
493    function In_Extended_Main_Source_Unit
494      (N : Node_Or_Entity_Id) return Boolean;
495    --  Return True if the node is in the source text of the extended main
496    --  unit, defined as the main unit, its specification (if any), and all
497    --  its subunits (considered recursively). Units for which this enquiry
498    --  returns True are those for which code will be generated. This differs
499    --  from In_Extended_Main_Code_Unit only in that instantiations are not
500    --  included for the purposes of this call. If the main unit is itself
501    --  a subunit, then the extended main unit includes its parent unit,
502    --  and the parent unit spec if it is separate.
503
504    function In_Extended_Main_Source_Unit (Loc : Source_Ptr) return Boolean;
505    --  Same function as above, but argument is a source pointer
506
507    function In_Predefined_Unit (N : Node_Or_Entity_Id) return Boolean;
508    --  Returns True if the given node or entity appears within the source text
509    --  of a predefined unit (i.e. within Ada, Interfaces, System or within one
510    --  of the descendent packages of one of these three packages).
511
512    function In_Predefined_Unit (S : Source_Ptr) return Boolean;
513    --  Same function as above but argument is a source pointer
514
515    function Earlier_In_Extended_Unit (S1, S2 : Source_Ptr) return Boolean;
516    --  Given two Sloc values for which In_Same_Extended_Unit is true, determine
517    --  if S1 appears before S2. Returns True if S1 appears before S2, and False
518    --  otherwise. The result is undefined if S1 and S2 are not in the same
519    --  extended unit. Note: this routine will not give reliable results if
520    --  called after Sprint has been called with -gnatD set.
521
522    function Compilation_Switches_Last return Nat;
523    --  Return the count of stored compilation switches
524
525    function Get_Compilation_Switch (N : Pos) return String_Ptr;
526    --  Return the Nth stored compilation switch, or null if less than N
527    --  switches have been stored. Used by ASIS and back ends written in Ada.
528
529    function Get_Cunit_Unit_Number (N : Node_Id) return Unit_Number_Type;
530    --  Return unit number of the unit whose N_Compilation_Unit node is the
531    --  one passed as an argument. This must always succeed since the node
532    --  could not have been built without making a unit table entry.
533
534    function Get_Cunit_Entity_Unit_Number
535      (E : Entity_Id) return Unit_Number_Type;
536    --  Return unit number of the unit whose compilation unit spec entity is
537    --  the one passed as an argument. This must always succeed since the
538    --  entity could not have been built without making a unit table entry.
539
540    function Increment_Serial_Number return Nat;
541    --  Increment Serial_Number field for current unit, and return the
542    --  incremented value.
543
544    procedure Synchronize_Serial_Number;
545    --  This function increments the Serial_Number field for the current unit
546    --  but does not return the incremented value. This is used when there
547    --  is a situation where one path of control increments a serial number
548    --  (using Increment_Serial_Number), and the other path does not and it is
549    --  important to keep the serial numbers synchronized in the two cases (e.g.
550    --  when the references in a package and a client must be kept consistent).
551
552    procedure Replace_Linker_Option_String
553      (S            : String_Id;
554       Match_String : String);
555    --  Replace an existing Linker_Option if the prefix Match_String matches,
556    --  otherwise call Store_Linker_Option_String.
557
558    procedure Store_Compilation_Switch (Switch : String);
559    --  Called to register a compilation switch, either front-end or back-end,
560    --  which may influence the generated output file(s). Switch is the text of
561    --  the switch to store (except that -fRTS gets changed back to --RTS).
562
563    procedure Enable_Switch_Storing;
564    --  Enable registration of switches by Store_Compilation_Switch. Used to
565    --  avoid registering switches added automatically by the gcc driver at the
566    --  beginning of the command line.
567
568    procedure Disable_Switch_Storing;
569    --  Disable registration of switches by Store_Compilation_Switch. Used to
570    --  avoid registering switches added automatically by the gcc driver at the
571    --  end of the command line.
572
573    procedure Store_Linker_Option_String (S : String_Id);
574    --  This procedure is called to register the string from a pragma
575    --  Linker_Option. The argument is the Id of the string to register.
576
577    procedure Initialize;
578    --  Initialize internal tables
579
580    procedure Lock;
581    --  Lock internal tables before calling back end
582
583    procedure Unlock;
584    --  Unlock internal tables, in cases where the back end needs to modify them
585
586    procedure Tree_Read;
587    --  Initializes internal tables from current tree file using the relevant
588    --  Table.Tree_Read routines.
589
590    procedure Tree_Write;
591    --  Writes out internal tables to current tree file using the relevant
592    --  Table.Tree_Write routines.
593
594    function Is_Loaded (Uname : Unit_Name_Type) return Boolean;
595    --  Determines if unit with given name is already loaded, i.e. there is
596    --  already an entry in the file table with this unit name for which the
597    --  corresponding file was found and parsed. Note that the Fatal_Error flag
598    --  of this entry must be checked before proceeding with further processing.
599
600    procedure Version_Referenced (S : String_Id);
601    --  This routine is called from Exp_Attr to register the use of a Version
602    --  or Body_Version attribute. The argument is the external name used to
603    --  access the version string.
604
605    procedure List (File_Names_Only : Boolean := False);
606    --  Lists units in active library (i.e. generates output consisting of a
607    --  sorted listing of the units represented in File table, except for the
608    --  main unit). If File_Names_Only is set to True, then the list includes
609    --  only file names, and no other information. Otherwise the unit name and
610    --  time stamp are also output. File_Names_Only also restricts the list to
611    --  exclude any predefined files.
612
613    function Generic_May_Lack_ALI (Sfile : File_Name_Type) return Boolean;
614    --  Generic units must be separately compiled. Since we always use
615    --  macro substitution for generics, the resulting object file is a dummy
616    --  one with no code, but the ALI file has the normal form, and we need
617    --  this ALI file so that the binder can work out a correct order of
618    --  elaboration.
619
620    --  However, ancient versions of GNAT used to not generate code or ALI
621    --  files for generic units, and this would yield complex order of
622    --  elaboration issues. These were fixed in GNAT 3.10. The support for not
623    --  compiling language-defined library generics was retained nonetheless
624    --  to facilitate bootstrap. Specifically, it is convenient to have
625    --  the same list of files to be compiled for all stages. So, if the
626    --  bootstrap compiler does not generate code for a given file, then
627    --  the stage1 compiler (and binder) also must deal with the case of
628    --  that file not being compiled. The predicate Generic_May_Lack_ALI is
629    --  True for those generic units for which missing ALI files are allowed.
630
631 private
632    pragma Inline (Cunit);
633    pragma Inline (Cunit_Entity);
634    pragma Inline (Dependency_Num);
635    pragma Inline (Fatal_Error);
636    pragma Inline (Generate_Code);
637    pragma Inline (Has_RACW);
638    pragma Inline (Is_Compiler_Unit);
639    pragma Inline (Increment_Serial_Number);
640    pragma Inline (Loading);
641    pragma Inline (Main_Priority);
642    pragma Inline (Munit_Index);
643    pragma Inline (OA_Setting);
644    pragma Inline (Set_Cunit);
645    pragma Inline (Set_Cunit_Entity);
646    pragma Inline (Set_Fatal_Error);
647    pragma Inline (Set_Generate_Code);
648    pragma Inline (Set_Has_RACW);
649    pragma Inline (Set_Loading);
650    pragma Inline (Set_Main_Priority);
651    pragma Inline (Set_OA_Setting);
652    pragma Inline (Set_Unit_Name);
653    pragma Inline (Source_Index);
654    pragma Inline (Unit_File_Name);
655    pragma Inline (Unit_Name);
656
657    type Unit_Record is record
658       Unit_File_Name   : File_Name_Type;
659       Unit_Name        : Unit_Name_Type;
660       Munit_Index      : Nat;
661       Expected_Unit    : Unit_Name_Type;
662       Source_Index     : Source_File_Index;
663       Cunit            : Node_Id;
664       Cunit_Entity     : Entity_Id;
665       Dependency_Num   : Int;
666       Ident_String     : Node_Id;
667       Main_Priority    : Int;
668       Serial_Number    : Nat;
669       Version          : Word;
670       Error_Location   : Source_Ptr;
671       Fatal_Error      : Boolean;
672       Generate_Code    : Boolean;
673       Has_RACW         : Boolean;
674       Is_Compiler_Unit : Boolean;
675       Dynamic_Elab     : Boolean;
676       Loading          : Boolean;
677       OA_Setting       : Character;
678    end record;
679
680    --  The following representation clause ensures that the above record
681    --  has no holes. We do this so that when instances of this record are
682    --  written by Tree_Gen, we do not write uninitialized values to the file.
683
684    for Unit_Record use record
685       Unit_File_Name   at  0 range 0 .. 31;
686       Unit_Name        at  4 range 0 .. 31;
687       Munit_Index      at  8 range 0 .. 31;
688       Expected_Unit    at 12 range 0 .. 31;
689       Source_Index     at 16 range 0 .. 31;
690       Cunit            at 20 range 0 .. 31;
691       Cunit_Entity     at 24 range 0 .. 31;
692       Dependency_Num   at 28 range 0 .. 31;
693       Ident_String     at 32 range 0 .. 31;
694       Main_Priority    at 36 range 0 .. 31;
695       Serial_Number    at 40 range 0 .. 31;
696       Version          at 44 range 0 .. 31;
697       Error_Location   at 48 range 0 .. 31;
698       Fatal_Error      at 52 range 0 ..  7;
699       Generate_Code    at 53 range 0 ..  7;
700       Has_RACW         at 54 range 0 ..  7;
701       Dynamic_Elab     at 55 range 0 ..  7;
702       Is_Compiler_Unit at 56 range 0 ..  7;
703       OA_Setting       at 57 range 0 ..  7;
704       Loading          at 58 range 0 .. 15;
705    end record;
706
707    for Unit_Record'Size use 60 * 8;
708    --  This ensures that we did not leave out any fields
709
710    package Units is new Table.Table (
711      Table_Component_Type => Unit_Record,
712      Table_Index_Type     => Unit_Number_Type,
713      Table_Low_Bound      => Main_Unit,
714      Table_Initial        => Alloc.Units_Initial,
715      Table_Increment      => Alloc.Units_Increment,
716      Table_Name           => "Units");
717
718    --  The following table stores strings from pragma Linker_Option lines
719
720    type Linker_Option_Entry is record
721       Option : String_Id;
722       --  The string for the linker option line
723
724       Unit : Unit_Number_Type;
725       --  The unit from which the linker option comes
726    end record;
727
728    package Linker_Option_Lines is new Table.Table (
729      Table_Component_Type => Linker_Option_Entry,
730      Table_Index_Type     => Integer,
731      Table_Low_Bound      => 1,
732      Table_Initial        => Alloc.Linker_Option_Lines_Initial,
733      Table_Increment      => Alloc.Linker_Option_Lines_Increment,
734      Table_Name           => "Linker_Option_Lines");
735
736    --  The following table records the compilation switches used to compile
737    --  the main unit. The table includes only switches and excludes -quiet,
738    --  -dumpbase, and -o switches, since the latter are typically artifacts
739    --  of the gcc/gnat1 interface.
740
741    --  This table is set as part of the compiler argument scanning in
742    --  Back_End. It can also be reset in -gnatc mode from the data in an
743    --  existing ali file, and is read and written by the Tree_Read and
744    --  Tree_Write routines for ASIS.
745
746    package Compilation_Switches is new Table.Table (
747      Table_Component_Type => String_Ptr,
748      Table_Index_Type     => Nat,
749      Table_Low_Bound      => 1,
750      Table_Initial        => 30,
751      Table_Increment      => 100,
752      Table_Name           => "Compilation_Switches");
753
754    Load_Msg_Sloc : Source_Ptr;
755    --  Location for placing error messages (a token in the main source text)
756    --  This is set from Sloc (Enode) by Load only in the case where this Sloc
757    --  is in the main source file. This ensures that not found messages and
758    --  circular dependency messages reference the original with in this source.
759
760    type Unit_Ref_Table is array (Pos range <>) of Unit_Number_Type;
761    --  Type to hold list of indirect references to unit number table
762
763    type Load_Stack_Entry is record
764       Unit_Number : Unit_Number_Type;
765       With_Node   : Node_Id;
766    end record;
767
768    --  The Load_Stack table contains a list of unit numbers (indices into the
769    --  unit table) of units being loaded on a single dependency chain, and a
770    --  flag to indicate whether this unit is loaded through a limited_with
771    --  clause. The First entry is the main unit. The second entry, if present
772    --  is a unit on which the first unit depends, etc. This stack is used to
773    --  generate error messages showing the dependency chain if a file is not
774    --  found, or whether a true circular dependency exists.  The Load_Unit
775    --  function makes an entry in this table when it is called, and removes
776    --  the entry just before it returns.
777
778    package Load_Stack is new Table.Table (
779      Table_Component_Type => Load_Stack_Entry,
780      Table_Index_Type     => Int,
781      Table_Low_Bound      => 0,
782      Table_Initial        => Alloc.Load_Stack_Initial,
783      Table_Increment      => Alloc.Load_Stack_Increment,
784      Table_Name           => "Load_Stack");
785
786    procedure Sort (Tbl : in out Unit_Ref_Table);
787    --  This procedure sorts the given unit reference table in order of
788    --  ascending unit names, where the ordering relation is as described
789    --  by the comparison routines provided by package Uname.
790
791    --  The Version_Ref table records Body_Version and Version attribute
792    --  references. The entries are simply the strings for the external
793    --  names that correspond to the referenced values.
794
795    package Version_Ref is new Table.Table (
796      Table_Component_Type => String_Id,
797      Table_Index_Type     => Nat,
798      Table_Low_Bound      => 1,
799      Table_Initial        => 20,
800      Table_Increment      => 100,
801      Table_Name           => "Version_Ref");
802
803 end Lib;